[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fhXpvxmTNRNeV1Lh-3-oUJpJkLvVldwrJrmMl-31oqOQ":3,"g5a-ex:philips\u002Fintellivue_mx550@*":70,"g5a-family:philips\u002Fintellivue_mx550":72},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":47,"seoMetadata":48,"meta":67},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"philips","intellivue_mx550",0,5,"2020-09-11",[],"Intellivue Mx550 by Philips is a technology product and 5 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,24,31,37,42],{"cveId":17,"description":18,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":23},"CVE-2020-16216","In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, \nMX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, \nthe product receives input or data but does not validate or incorrectly \nvalidates that the input has the properties required to process the data\n safely and correctly, which can induce a denial-of-service condition \nthrough a system restart.\n\n\n\n",6.5,"v3.1","Medium",false,0.00698,{"cveId":25,"description":26,"publishedDate":27,"cvssScore":28,"cvssVersion":29,"severity":21,"isKev":22,"epssScore":30},"CVE-2018-10599","IntelliVue Patient Monitors MP Series (including MP2\u002FX2\u002FMP30\u002FMP50\u002FMP70\u002FNP90\u002FMX700\u002F800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3\u002FMX100 for Rev M only), and Avalon Fetal\u002FMaternal Monitors FM20\u002FFM30\u002FFM40\u002FFM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.","2018-06-05",5.3,"v3.0",0.00421,{"cveId":32,"description":33,"publishedDate":27,"cvssScore":34,"cvssVersion":20,"severity":35,"isKev":22,"epssScore":36},"CVE-2018-10597","IntelliVue Patient Monitors MP Series (including MP2\u002FX2\u002FMP30\u002FMP50\u002FMP70\u002FNP90\u002FMX700\u002F800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3\u002FMX100 for Rev M only), and Avalon Fetal\u002FMaternal Monitors FM20\u002FFM30\u002FFM40\u002FFM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\"write-what-where\") from an attacker-chosen device address within the same subnet.",8.3,"High",0.00397,{"cveId":38,"description":39,"publishedDate":27,"cvssScore":40,"cvssVersion":20,"severity":35,"isKev":22,"epssScore":41},"CVE-2018-10601","IntelliVue Patient Monitors MP Series (including MP2\u002FX2\u002FMP30\u002FMP50\u002FMP70\u002FNP90\u002FMX700\u002F800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3\u002FMX100 for Rev M only), and Avalon Fetal\u002FMaternal Monitors FM20\u002FFM30\u002FFM40\u002FFM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.",8.2,0.00372,{"cveId":43,"description":44,"publishedDate":11,"cvssScore":45,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":46},"CVE-2020-16228","In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.\n\n\n\n",6.4,0.00368,[],{"title":49,"metaDescription":50,"keywords":51,"structuredData":52},"Intellivue Mx550 by Philips - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Intellivue Mx550 by Philips with 5 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Intellivue Mx550 vulnerabilities, Intellivue Mx550 security, Intellivue Mx550 CVE, Philips Intellivue Mx550, Intellivue Mx550 threat intelligence, Philips security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":53,"@type":54,"name":55,"description":50,"url":56,"manufacturer":57,"applicationCategory":61,"softwareVersion":62,"mainEntity":63},"https:\u002F\u002Fschema.org","SoftwareApplication","Intellivue Mx550","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fphilips\u002Fintellivue_mx550",{"@type":58,"name":59,"url":60},"Organization","Philips","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fphilips","Security Software","Multiple versions",{"@type":64,"name":65,"description":66,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Intellivue Mx550 Security Vulnerabilities","Security vulnerabilities affecting Intellivue Mx550 by Philips",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":68,"apiVersion":69},"2026-10-18T18:24:31.751Z","3.0",{"rows":71,"total":9,"capped":22,"failed":9},[],[73],{"product":74,"cves":10},"intellivue_mx550_firmware"]