[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fbiSBXE7sDLSFWR5aUcZpdpcm2ZloT19qfXWL3zAfBEE":3,"g5a-ex:philips\u002Fpatient_information_center_ix@*":103,"g5a-family:philips\u002Fpatient_information_center_ix":105},{"success":4,"data":5},true,{"product":6,"versions":23,"topVulnerabilitiesByEpss":27,"kevVulnerabilities":80,"seoMetadata":81,"meta":100},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":22},"philips","patient_information_center_ix",3,11,0,"2021-12-27",[14,18,20],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"b.02",8,false,{"version":19,"cve_count":10,"kev_count":11,"has_kev":17},"c.02",{"version":21,"cve_count":10,"kev_count":11,"has_kev":17},"c.03","Patient Information Center Ix by Philips is a technology product with 3 tracked versions and 11 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[24,25,26],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":10,"kev_count":11,"has_kev":17},{"version":21,"cve_count":10,"kev_count":11,"has_kev":17},[28,36,42,46,51,57,62,67,71,76],{"cveId":29,"description":30,"publishedDate":31,"cvssScore":32,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":35},"CVE-2020-16216","In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, \nMX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, \nthe product receives input or data but does not validate or incorrectly \nvalidates that the input has the properties required to process the data\n safely and correctly, which can induce a denial-of-service condition \nthrough a system restart.\n\n\n\n","2020-09-11",6.5,"v3.1","Medium",0.00698,{"cveId":37,"description":38,"publishedDate":31,"cvssScore":39,"cvssVersion":33,"severity":40,"isKev":17,"epssScore":41},"CVE-2020-16218","In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the \nsoftware does not neutralize or incorrectly neutralizes \nuser-controllable input before it is placed in output that is then used \nas a webpage and served to other users. Successful exploitation could \nlead to unauthorized access to patient data via a read-only web \napplication.\n\n\n\n",3.5,"Low",0.00653,{"cveId":43,"description":44,"publishedDate":31,"cvssScore":32,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":45},"CVE-2020-16224","In Patient Information Center iX (PICiX) Versions C.02, C.03, the \nsoftware parses a formatted message or structure but does not handle or \nincorrectly handles a length field that is inconsistent with the actual \nlength of the associated data, causing the application on the \nsurveillance station to restart.\n\n\n\n",0.00594,{"cveId":47,"description":48,"publishedDate":31,"cvssScore":49,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":50},"CVE-2020-16214","In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the \nsoftware saves user-provided information into a comma-separated value \n(CSV) file, but it does not neutralize or incorrectly neutralizes \nspecial elements that could be interpreted as a command when the file is\n opened by spreadsheet software.\n\n\n\n",5,0.00586,{"cveId":52,"description":53,"publishedDate":31,"cvssScore":54,"cvssVersion":33,"severity":55,"isKev":17,"epssScore":56},"CVE-2020-16222","In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct.\n\n",8.8,"High",0.00549,{"cveId":58,"description":59,"publishedDate":31,"cvssScore":60,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":61},"CVE-2020-16212","In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.",6.8,0.00371,{"cveId":63,"description":64,"publishedDate":31,"cvssScore":65,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":66},"CVE-2020-16228","In Patient Information Center iX (PICiX) Versions C.02 and C.03, \nPerformanceBridge Focal Point Version A.01, IntelliVue patient monitors \nMX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and \nprior, the software does not check or incorrectly checks the revocation \nstatus of a certificate, which may cause it to use a compromised \ncertificate.\n\n\n\n",6.4,0.00368,{"cveId":68,"description":69,"publishedDate":12,"cvssScore":32,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":70},"CVE-2021-43548","Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.",0.00366,{"cveId":72,"description":73,"publishedDate":31,"cvssScore":74,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":75},"CVE-2020-16220","In Patient Information Center iX (PICiX) Versions C.02, C.03, \nPerformanceBridge Focal Point Version A.01, the product receives input \nthat is expected to be well-formed (i.e., to comply with a certain \nsyntax) but it does not validate or incorrectly validates that the input\n complies with the syntax, causing the certificate enrollment service to\n crash. It does not impact monitoring but prevents new devices from \nenrolling.\n\n\n\n",4.3,0.0028,{"cveId":77,"description":78,"publishedDate":12,"cvssScore":32,"cvssVersion":33,"severity":34,"isKev":17,"epssScore":79},"CVE-2021-43550","The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.",0.00219,[],{"title":82,"metaDescription":83,"keywords":84,"structuredData":85},"Patient Information Center Ix by Philips - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Patient Information Center Ix by Philips covering 3 versions with 11 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Patient Information Center Ix vulnerabilities, Patient Information Center Ix security, Patient Information Center Ix CVE, Philips Patient Information Center Ix, Patient Information Center Ix threat intelligence, Philips security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":86,"@type":87,"name":88,"description":83,"url":89,"manufacturer":90,"applicationCategory":94,"softwareVersion":95,"mainEntity":96},"https:\u002F\u002Fschema.org","SoftwareApplication","Patient Information Center Ix","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fphilips\u002Fpatient_information_center_ix",{"@type":91,"name":92,"url":93},"Organization","Philips","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fphilips","Security Software","3 versions tracked",{"@type":97,"name":98,"description":99,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Patient Information Center Ix Security Vulnerabilities","Security vulnerabilities affecting Patient Information Center Ix by Philips",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":101,"apiVersion":102},"2026-10-18T20:45:48.348Z","3.0",{"rows":104,"total":11,"capped":17,"failed":11},[],[]]