[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fGsaMPmqJZnc7mrNno-lpH5EXBK3cmHFmA1xg2ml2sIg":3,"g5a-ex:rockwellautomation\u002F1756-enbt@*":87,"g5a-family:rockwellautomation\u002F1756-enbt":89},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":65,"seoMetadata":66,"meta":84},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"rockwellautomation","1756-enbt",0,9,"2018-12-07",[],"1756-enbt by Rockwellautomation is a technology product and 9 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,32,36,40,44,49,54,60],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2012-6441","An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP. Successful exploitation of this vulnerability could cause loss of confidentiality.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400","2013-01-24",5,"v2","Medium",false,0.57148,{"cveId":26,"description":27,"publishedDate":19,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":23,"epssScore":31},"CVE-2012-6442","When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",7.5,"v3.1","High",0.35549,{"cveId":33,"description":34,"publishedDate":19,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":23,"epssScore":35},"CVE-2012-6435","When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",0.33499,{"cveId":37,"description":38,"publishedDate":19,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":23,"epssScore":39},"CVE-2012-6438","The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",0.27374,{"cveId":41,"description":42,"publishedDate":19,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":23,"epssScore":43},"CVE-2012-6436","The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port 44818\u002FUDP, which creates a buffer overflow and causes the CPU to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices.\n\n\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",0.27116,{"cveId":45,"description":46,"publishedDate":19,"cvssScore":47,"cvssVersion":21,"severity":30,"isKev":23,"epssScore":48},"CVE-2012-6439","When an affected \nproduct receives a valid CIP message from an unauthorized or unintended \nsource to Port 2222\u002FTCP, Port 2222\u002FUDP, Port 44818\u002FTCP, or Port \n44818\u002FUDP that changes the product’s configuration and network \nparameters, a DoS condition can occur. This situation could cause loss \nof availability and a disruption of communication with other connected \ndevices. \n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",8.5,0.2318,{"cveId":50,"description":51,"publishedDate":19,"cvssScore":52,"cvssVersion":29,"severity":22,"isKev":23,"epssScore":53},"CVE-2012-6440","The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information.\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",4.8,0.0926,{"cveId":55,"description":56,"publishedDate":19,"cvssScore":57,"cvssVersion":29,"severity":58,"isKev":23,"epssScore":59},"CVE-2012-6437","The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices.\n\n\n\n\n\nRockwell Automation EtherNet\u002FIP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I\u002FO EtherNet\u002FIP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400",9.8,"Critical",0.07845,{"cveId":61,"description":62,"publishedDate":11,"cvssScore":63,"cvssVersion":29,"severity":30,"isKev":23,"epssScore":64},"CVE-2018-17924","Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.",8.6,0.04335,[],{"title":67,"metaDescription":68,"keywords":69,"structuredData":70},"1756-enbt by Rockwellautomation - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for 1756-enbt by Rockwellautomation with 9 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","1756-enbt vulnerabilities, 1756-enbt security, 1756-enbt CVE, Rockwellautomation 1756-enbt, 1756-enbt threat intelligence, Rockwellautomation security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":71,"@type":72,"name":8,"description":68,"url":73,"manufacturer":74,"applicationCategory":78,"softwareVersion":79,"mainEntity":80},"https:\u002F\u002Fschema.org","SoftwareApplication","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Frockwellautomation\u002F1756-enbt",{"@type":75,"name":76,"url":77},"Organization","Rockwellautomation","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Frockwellautomation","Security Software","Multiple versions",{"@type":81,"name":82,"description":83,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","1756-enbt Security Vulnerabilities","Security vulnerabilities affecting 1756-enbt by Rockwellautomation",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":85,"apiVersion":86},"2026-10-18T14:18:45.634Z","3.0",{"rows":88,"total":9,"capped":23,"failed":9},[],[90],{"product":91,"cves":92},"1756-enbt_firmware",1]