[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fCxqI9ekWvZMBXVyAimqDYMY-jQG6qCXeLgTouc1txuY":3,"g5a-family:rockwellautomation\u002Fcompact_guardlogix_5380":94,"g5a-ex:rockwellautomation\u002Fcompact_guardlogix_5380@*":107},{"success":4,"data":5},true,{"product":6,"versions":15,"topVulnerabilitiesByEpss":16,"kevVulnerabilities":66,"seoMetadata":72,"meta":91},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":14},"rockwellautomation","compact_guardlogix_5380",0,8,1,"2024-10-08",[],"Compact Guardlogix 5380 by Rockwellautomation is a technology product and 8 known security vulnerabilities including 1 CISA Known Exploited Vulnerability. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[17,25,31,38,44,50,55,60],{"cveId":18,"description":19,"publishedDate":20,"cvssScore":21,"cvssVersion":22,"severity":23,"isKev":4,"epssScore":24},"CVE-2021-22681","Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.","2021-03-03",9.8,"v3.1","Critical",0.6363,{"cveId":26,"description":27,"publishedDate":28,"cvssScore":21,"cvssVersion":22,"severity":23,"isKev":29,"epssScore":30},"CVE-2022-1161","An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.","2022-04-11",false,0.05213,{"cveId":32,"description":33,"publishedDate":34,"cvssScore":35,"cvssVersion":22,"severity":36,"isKev":29,"epssScore":37},"CVE-2022-1159","Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.","2022-04-01",7.2,"High",0.0345,{"cveId":39,"description":40,"publishedDate":41,"cvssScore":42,"cvssVersion":22,"severity":36,"isKev":29,"epssScore":43},"CVE-2022-1797","A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.","2022-06-02",8.6,0.02127,{"cveId":45,"description":46,"publishedDate":47,"cvssScore":48,"cvssVersion":22,"severity":36,"isKev":29,"epssScore":49},"CVE-2022-3157","\nA vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). \n\n","2022-12-16",7.5,0.01525,{"cveId":51,"description":52,"publishedDate":53,"cvssScore":48,"cvssVersion":22,"severity":36,"isKev":29,"epssScore":54},"CVE-2022-3752","An unauthorized user could use a specially crafted sequence of Ethernet\u002FIP messages, combined with heavy traffic \nloading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload \nthe user project file to bring the device back online and continue normal operation.\n\n\n","2022-12-19",0.01255,{"cveId":56,"description":57,"publishedDate":58,"cvssScore":42,"cvssVersion":22,"severity":36,"isKev":29,"epssScore":59},"CVE-2024-3493","\nA specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and\u002For control of connected devices. \n\n","2024-04-15",0.00637,{"cveId":61,"description":62,"publishedDate":12,"cvssScore":63,"cvssVersion":64,"severity":36,"isKev":29,"epssScore":65},"CVE-2024-8626","Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover.",8.7,"v4.0",0.00521,[67],{"cveId":18,"description":19,"publishedDate":20,"cvssScore":21,"severity":23,"isKev":4,"epssScore":24,"cisaVulnName":68,"cisaDateAdded":69,"cisaShortDescription":70,"cisaRequiredAction":71},"Rockwell Multiple Products Insufficient Protected Credentials Vulnerability","2026-03-05","Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.","Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.",{"title":73,"metaDescription":74,"keywords":75,"structuredData":76},"Compact Guardlogix 5380 by Rockwellautomation - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Compact Guardlogix 5380 by Rockwellautomation with 8 tracked vulnerabilities including 1 critical and 0 high-severity issues and 1 CISA KEV vulnerability. Real-time threat intelligence, CVE tracking, and security recommendations.","Compact Guardlogix 5380 vulnerabilities, Compact Guardlogix 5380 security, Compact Guardlogix 5380 CVE, Rockwellautomation Compact Guardlogix 5380, Compact Guardlogix 5380 threat intelligence, Rockwellautomation security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking, Compact Guardlogix 5380 KEV, Compact Guardlogix 5380 exploited vulnerabilities",{"@context":77,"@type":78,"name":79,"description":74,"url":80,"manufacturer":81,"applicationCategory":85,"softwareVersion":86,"mainEntity":87},"https:\u002F\u002Fschema.org","SoftwareApplication","Compact Guardlogix 5380","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Frockwellautomation\u002Fcompact_guardlogix_5380",{"@type":82,"name":83,"url":84},"Organization","Rockwellautomation","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Frockwellautomation","Security Software","Multiple versions",{"@type":88,"name":89,"description":90,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Compact Guardlogix 5380 Security Vulnerabilities","Security vulnerabilities affecting Compact Guardlogix 5380 by Rockwellautomation",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":92,"apiVersion":93},"2026-10-17T17:50:02.023Z","3.0",[95,98,101,103,105],{"product":96,"cves":97},"compact_guardlogix_5380_firmware",7,{"product":99,"cves":100},"compact_guardlogix_5380_sil_2",4,{"product":102,"cves":100},"compact_guardlogix_5380_sil_2_firmware",{"product":104,"cves":100},"compact_guardlogix_5380_sil_3",{"product":106,"cves":100},"compact_guardlogix_5380_sil_3_firmware",{"rows":108,"total":11,"capped":29,"failed":9},[109],{"cveId":18,"name":68,"severity":23,"cvss":21,"added":69,"epss":24,"published":110,"ranges":111,"checked":4,"hits":112,"covers":29},"2021-03-03T18:15:14.643",[],[]]