[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$frRHj1VOgM-nzrXvNVlhb0j-Lx6tCZVdgaqKn960NjfQ":3,"g5a-family:rockwellautomation\u002Fcontrollogix_5570":78,"g5a-ex:rockwellautomation\u002Fcontrollogix_5570@*":95},{"success":4,"data":5},true,{"product":6,"versions":15,"topVulnerabilitiesByEpss":16,"kevVulnerabilities":50,"seoMetadata":56,"meta":75},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":14},"rockwellautomation","controllogix_5570",0,5,1,"2022-12-16",[],"Controllogix 5570 by Rockwellautomation is a technology product and 5 known security vulnerabilities including 1 CISA Known Exploited Vulnerability. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[17,25,31,38,45],{"cveId":18,"description":19,"publishedDate":20,"cvssScore":21,"cvssVersion":22,"severity":23,"isKev":4,"epssScore":24},"CVE-2021-22681","Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.","2021-03-03",9.8,"v3.1","Critical",0.6363,{"cveId":26,"description":27,"publishedDate":28,"cvssScore":21,"cvssVersion":22,"severity":23,"isKev":29,"epssScore":30},"CVE-2022-1161","An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.","2022-04-11",false,0.05213,{"cveId":32,"description":33,"publishedDate":34,"cvssScore":35,"cvssVersion":22,"severity":36,"isKev":29,"epssScore":37},"CVE-2020-6998","The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.","2022-07-27",5.8,"Medium",0.0316,{"cveId":39,"description":40,"publishedDate":41,"cvssScore":42,"cvssVersion":22,"severity":43,"isKev":29,"epssScore":44},"CVE-2022-1797","A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.","2022-06-02",8.6,"High",0.02127,{"cveId":46,"description":47,"publishedDate":12,"cvssScore":48,"cvssVersion":22,"severity":43,"isKev":29,"epssScore":49},"CVE-2022-3157","\nA vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). \n\n",7.5,0.01525,[51],{"cveId":18,"description":19,"publishedDate":20,"cvssScore":21,"severity":23,"isKev":4,"epssScore":24,"cisaVulnName":52,"cisaDateAdded":53,"cisaShortDescription":54,"cisaRequiredAction":55},"Rockwell Multiple Products Insufficient Protected Credentials Vulnerability","2026-03-05","Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.","Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.",{"title":57,"metaDescription":58,"keywords":59,"structuredData":60},"Controllogix 5570 by Rockwellautomation - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Controllogix 5570 by Rockwellautomation with 5 tracked vulnerabilities including 1 critical and 0 high-severity issues and 1 CISA KEV vulnerability. Real-time threat intelligence, CVE tracking, and security recommendations.","Controllogix 5570 vulnerabilities, Controllogix 5570 security, Controllogix 5570 CVE, Rockwellautomation Controllogix 5570, Controllogix 5570 threat intelligence, Rockwellautomation security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking, Controllogix 5570 KEV, Controllogix 5570 exploited vulnerabilities",{"@context":61,"@type":62,"name":63,"description":58,"url":64,"manufacturer":65,"applicationCategory":69,"softwareVersion":70,"mainEntity":71},"https:\u002F\u002Fschema.org","SoftwareApplication","Controllogix 5570","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Frockwellautomation\u002Fcontrollogix_5570",{"@type":66,"name":67,"url":68},"Organization","Rockwellautomation","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Frockwellautomation","Security Software","Multiple versions",{"@type":72,"name":73,"description":74,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Controllogix 5570 Security Vulnerabilities","Security vulnerabilities affecting Controllogix 5570 by Rockwellautomation",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":76,"apiVersion":77},"2026-10-18T15:58:25.122Z","3.0",[79,82,85,87,89,91,93],{"product":80,"cves":81},"controllogix_5570_firmware",4,{"product":83,"cves":84},"controllogix_5570_redundant_controller",2,{"product":86,"cves":84},"controllogix_5570_redundant_controller_firmware",{"product":88,"cves":84},"controllogix_5570_controller",{"product":90,"cves":84},"controllogix_5570_controller_firmware",{"product":92,"cves":11},"controllogix_5570_redundancy",{"product":94,"cves":11},"controllogix_5570_redundancy_firmware",{"rows":96,"total":11,"capped":29,"failed":9},[97],{"cveId":18,"name":52,"severity":23,"cvss":21,"added":53,"epss":24,"published":98,"ranges":99,"checked":4,"hits":100,"covers":29},"2021-03-03T18:15:14.643",[],[]]