[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fU1CEp9xp7lbkj8grEpGBpGEY3PckKP9dbyrSV85K8ZU":3,"g5a-ex:rockwellautomation\u002Fcontrollogix_5580_firmware@*":156,"g5a-family:rockwellautomation\u002Fcontrollogix_5580_firmware":158},{"success":4,"data":5},true,{"product":6,"versions":54,"topVulnerabilitiesByEpss":73,"kevVulnerabilities":133,"seoMetadata":134,"meta":153},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":53},"rockwellautomation","controllogix_5580_firmware",18,12,0,"2025-09-09",[14,17,19,22,24,26,28,30,32,34,37,39,41,43,45,47,49,51],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"28.011",false,{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},"32.013",{"version":20,"cve_count":21,"kev_count":11,"has_kev":16},"33.011",1,{"version":23,"cve_count":11,"kev_count":11,"has_kev":16},"33.012",{"version":25,"cve_count":11,"kev_count":11,"has_kev":16},"33.015",{"version":27,"cve_count":11,"kev_count":11,"has_kev":16},"33.017",{"version":29,"cve_count":21,"kev_count":11,"has_kev":16},"34.011",{"version":31,"cve_count":11,"kev_count":11,"has_kev":16},"34.014",{"version":33,"cve_count":11,"kev_count":11,"has_kev":16},"34.015",{"version":35,"cve_count":36,"kev_count":11,"has_kev":16},"35.011",3,{"version":38,"cve_count":21,"kev_count":11,"has_kev":16},"35.013",{"version":40,"cve_count":11,"kev_count":11,"has_kev":16},"35.014",{"version":42,"cve_count":11,"kev_count":11,"has_kev":16},"36.011",{"version":44,"cve_count":11,"kev_count":11,"has_kev":16},"37.011",{"version":46,"cve_count":21,"kev_count":11,"has_kev":16},"v28.011",{"version":48,"cve_count":21,"kev_count":11,"has_kev":16},"v28.012",{"version":50,"cve_count":21,"kev_count":11,"has_kev":16},"v28.013",{"version":52,"cve_count":21,"kev_count":11,"has_kev":16},"v29.011","Controllogix 5580 Firmware by Rockwellautomation is a technology product with 18 tracked versions and 12 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},{"version":20,"cve_count":21,"kev_count":11,"has_kev":16},{"version":23,"cve_count":11,"kev_count":11,"has_kev":16},{"version":25,"cve_count":11,"kev_count":11,"has_kev":16},{"version":27,"cve_count":11,"kev_count":11,"has_kev":16},{"version":29,"cve_count":21,"kev_count":11,"has_kev":16},{"version":31,"cve_count":11,"kev_count":11,"has_kev":16},{"version":33,"cve_count":11,"kev_count":11,"has_kev":16},{"version":35,"cve_count":36,"kev_count":11,"has_kev":16},{"version":38,"cve_count":21,"kev_count":11,"has_kev":16},{"version":40,"cve_count":11,"kev_count":11,"has_kev":16},{"version":42,"cve_count":11,"kev_count":11,"has_kev":16},{"version":44,"cve_count":11,"kev_count":11,"has_kev":16},{"version":46,"cve_count":21,"kev_count":11,"has_kev":16},{"version":48,"cve_count":21,"kev_count":11,"has_kev":16},{"version":50,"cve_count":21,"kev_count":11,"has_kev":16},{"version":52,"cve_count":21,"kev_count":11,"has_kev":16},[74,82,89,96,102,107,114,119,124,129],{"cveId":75,"description":76,"publishedDate":77,"cvssScore":78,"cvssVersion":79,"severity":80,"isKev":16,"epssScore":81},"CVE-2022-1161","An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.","2022-04-11",9.8,"v3.1","Critical",0.05213,{"cveId":83,"description":84,"publishedDate":85,"cvssScore":86,"cvssVersion":79,"severity":87,"isKev":16,"epssScore":88},"CVE-2022-1159","Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.","2022-04-01",7.2,"High",0.0345,{"cveId":90,"description":91,"publishedDate":92,"cvssScore":93,"cvssVersion":79,"severity":94,"isKev":16,"epssScore":95},"CVE-2017-6024","A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller.","2017-05-06",5.9,"Medium",0.02633,{"cveId":97,"description":98,"publishedDate":99,"cvssScore":100,"cvssVersion":79,"severity":87,"isKev":16,"epssScore":101},"CVE-2022-1797","A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online.","2022-06-02",8.6,0.02127,{"cveId":103,"description":104,"publishedDate":105,"cvssScore":100,"cvssVersion":79,"severity":87,"isKev":16,"epssScore":106},"CVE-2024-3493","\nA specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and\u002For control of connected devices. \n\n","2024-04-15",0.00637,{"cveId":108,"description":109,"publishedDate":110,"cvssScore":111,"cvssVersion":112,"severity":87,"isKev":16,"epssScore":113},"CVE-2024-40619","CVE-2024-40619 IMPACT\n\nA denial-of-service vulnerability exists in the affected products. The vulnerability occurs when a malformed CIP packet is sent over the network to the device and results in a major nonrecoverable fault causing a denial-of-service.","2024-08-14",8.7,"v4.0",0.00577,{"cveId":115,"description":116,"publishedDate":117,"cvssScore":111,"cvssVersion":112,"severity":87,"isKev":16,"epssScore":118},"CVE-2024-6077","A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover.","2024-09-12",0.00558,{"cveId":120,"description":121,"publishedDate":122,"cvssScore":111,"cvssVersion":112,"severity":87,"isKev":16,"epssScore":123},"CVE-2024-6207","CVE 2021-22681 https:\u002F\u002Fwww.rockwellautomation.com\u002Fen-us\u002Ftrust-center\u002Fsecurity-advisories\u002Fadvisory.PN1550.html  and send a specially crafted CIP message to the device.  If exploited, a threat actor could help prevent access to the legitimate user and end connections to connected devices including the workstation.  To recover the controllers, a download is required which ends any process that the controller is running.","2024-10-14",0.00551,{"cveId":125,"description":126,"publishedDate":127,"cvssScore":111,"cvssVersion":112,"severity":87,"isKev":16,"epssScore":128},"CVE-2024-8626","Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the product causing the affected products to become fully unavailable and require a power cycle to recover.","2024-10-08",0.00521,{"cveId":130,"description":131,"publishedDate":110,"cvssScore":111,"cvssVersion":112,"severity":87,"isKev":16,"epssScore":132},"CVE-2024-7515","CVE-2024-7515 IMPACT\n\nA denial-of-service vulnerability exists in the affected products. A malformed PTP management packet can cause a major nonrecoverable fault in the controller.",0.00517,[],{"title":135,"metaDescription":136,"keywords":137,"structuredData":138},"Controllogix 5580 Firmware by Rockwellautomation - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Controllogix 5580 Firmware by Rockwellautomation covering 18 versions with 12 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Controllogix 5580 Firmware vulnerabilities, Controllogix 5580 Firmware security, Controllogix 5580 Firmware CVE, Rockwellautomation Controllogix 5580 Firmware, Controllogix 5580 Firmware threat intelligence, Rockwellautomation security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":139,"@type":140,"name":141,"description":136,"url":142,"manufacturer":143,"applicationCategory":147,"softwareVersion":148,"mainEntity":149},"https:\u002F\u002Fschema.org","SoftwareApplication","Controllogix 5580 Firmware","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Frockwellautomation\u002Fcontrollogix_5580_firmware",{"@type":144,"name":145,"url":146},"Organization","Rockwellautomation","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Frockwellautomation","Security Software","18 versions tracked",{"@type":150,"name":151,"description":152,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Controllogix 5580 Firmware Security Vulnerabilities","Security vulnerabilities affecting Controllogix 5580 Firmware by Rockwellautomation",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":154,"apiVersion":155},"2026-10-18T13:28:09.728Z","3.0",{"rows":157,"total":11,"capped":16,"failed":11},[],[]]