[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fD8_EM_CRr_LHmltOHBayuvZHvHNQ93CLnf7B3yScrNk":3,"g5a-family:rockwellautomation\u002Ffactorytalk_services_platform":141,"g5a-ex:rockwellautomation\u002Ffactorytalk_services_platform@*":142},{"success":4,"data":5},true,{"product":6,"versions":40,"topVulnerabilitiesByEpss":52,"kevVulnerabilities":113,"seoMetadata":119,"meta":138},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":39},"rockwellautomation","factorytalk_services_platform",11,13,1,"2024-02-16",[14,18,20,22,24,26,28,30,32,34,36],{"version":15,"cve_count":16,"kev_count":16,"has_kev":17},"2.51.00.8",0,false,{"version":19,"cve_count":16,"kev_count":16,"has_kev":17},"2.61",{"version":21,"cve_count":16,"kev_count":16,"has_kev":17},"2.71",{"version":23,"cve_count":16,"kev_count":16,"has_kev":17},"2.73",{"version":25,"cve_count":16,"kev_count":16,"has_kev":17},"2.74",{"version":27,"cve_count":16,"kev_count":16,"has_kev":17},"2.80",{"version":29,"cve_count":16,"kev_count":16,"has_kev":17},"2.90",{"version":31,"cve_count":11,"kev_count":16,"has_kev":17},"6.10.00",{"version":33,"cve_count":11,"kev_count":16,"has_kev":17},"6.11.00",{"version":35,"cve_count":16,"kev_count":16,"has_kev":17},"6.31.00",{"version":37,"cve_count":38,"kev_count":16,"has_kev":17},"cpr9",2,"Factorytalk Services Platform by Rockwellautomation is a technology product with 11 tracked versions and 13 known security vulnerabilities including 1 CISA Known Exploited Vulnerability. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[41,42,43,44,45,46,47,48,49,50,51],{"version":15,"cve_count":16,"kev_count":16,"has_kev":17},{"version":19,"cve_count":16,"kev_count":16,"has_kev":17},{"version":21,"cve_count":16,"kev_count":16,"has_kev":17},{"version":23,"cve_count":16,"kev_count":16,"has_kev":17},{"version":25,"cve_count":16,"kev_count":16,"has_kev":17},{"version":27,"cve_count":16,"kev_count":16,"has_kev":17},{"version":29,"cve_count":16,"kev_count":16,"has_kev":17},{"version":31,"cve_count":11,"kev_count":16,"has_kev":17},{"version":33,"cve_count":11,"kev_count":16,"has_kev":17},{"version":35,"cve_count":16,"kev_count":16,"has_kev":17},{"version":37,"cve_count":38,"kev_count":16,"has_kev":17},[53,61,66,72,80,87,90,96,102,108],{"cveId":54,"description":55,"publishedDate":56,"cvssScore":57,"cvssVersion":58,"severity":59,"isKev":4,"epssScore":60},"CVE-2021-22681","Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800.","2021-03-03",9.8,"v3.1","Critical",0.6363,{"cveId":62,"description":63,"publishedDate":64,"cvssScore":57,"cvssVersion":58,"severity":59,"isKev":17,"epssScore":65},"CVE-2020-6967","In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp\u002F8082, which can insecurely deserialize untrusted data.","2020-03-23",0.05497,{"cveId":67,"description":68,"publishedDate":69,"cvssScore":70,"cvssVersion":58,"severity":59,"isKev":17,"epssScore":71},"CVE-2020-14516","In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user password from being hashed properly.","2021-03-18",10,0.0424,{"cveId":73,"description":74,"publishedDate":75,"cvssScore":76,"cvssVersion":77,"severity":78,"isKev":17,"epssScore":79},"CVE-2018-18981","In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.","2019-01-24",7.5,"v3.0","High",0.03866,{"cveId":81,"description":82,"publishedDate":83,"cvssScore":84,"cvssVersion":85,"severity":78,"isKev":17,"epssScore":86},"CVE-2012-4713","Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a negative integer value.","2013-04-18",7.8,"v2",0.03221,{"cveId":88,"description":89,"publishedDate":83,"cvssScore":84,"cvssVersion":85,"severity":78,"isKev":17,"epssScore":86},"CVE-2012-4714","Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value.",{"cveId":91,"description":92,"publishedDate":93,"cvssScore":94,"cvssVersion":58,"severity":78,"isKev":17,"epssScore":95},"CVE-2023-46290","\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.\n\n","2023-10-27",8.1,0.02724,{"cveId":97,"description":98,"publishedDate":99,"cvssScore":100,"cvssVersion":58,"severity":78,"isKev":17,"epssScore":101},"CVE-2021-32960","Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.","2022-04-01",8.5,0.02433,{"cveId":103,"description":104,"publishedDate":105,"cvssScore":106,"cvssVersion":58,"severity":78,"isKev":17,"epssScore":107},"CVE-2020-12033","In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges.","2020-06-23",8.8,0.01097,{"cveId":109,"description":110,"publishedDate":12,"cvssScore":111,"cvssVersion":58,"severity":59,"isKev":17,"epssScore":112},"CVE-2024-21915","\nA privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable.\n\n",9,0.0099,[114],{"cveId":54,"description":55,"publishedDate":56,"cvssScore":57,"severity":59,"isKev":4,"epssScore":60,"cisaVulnName":115,"cisaDateAdded":116,"cisaShortDescription":117,"cisaRequiredAction":118},"Rockwell Multiple Products Insufficient Protected Credentials Vulnerability","2026-03-05","Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.","Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.",{"title":120,"metaDescription":121,"keywords":122,"structuredData":123},"Factorytalk Services Platform by Rockwellautomation - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Factorytalk Services Platform by Rockwellautomation covering 11 versions with 13 tracked vulnerabilities including 1 critical and 0 high-severity issues and 1 CISA KEV vulnerability. Real-time threat intelligence, CVE tracking, and security recommendations.","Factorytalk Services Platform vulnerabilities, Factorytalk Services Platform security, Factorytalk Services Platform CVE, Rockwellautomation Factorytalk Services Platform, Factorytalk Services Platform threat intelligence, Rockwellautomation security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking, Factorytalk Services Platform KEV, Factorytalk Services Platform exploited vulnerabilities",{"@context":124,"@type":125,"name":126,"description":121,"url":127,"manufacturer":128,"applicationCategory":132,"softwareVersion":133,"mainEntity":134},"https:\u002F\u002Fschema.org","SoftwareApplication","Factorytalk Services Platform","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Frockwellautomation\u002Ffactorytalk_services_platform",{"@type":129,"name":130,"url":131},"Organization","Rockwellautomation","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Frockwellautomation","Security Software","11 versions tracked",{"@type":135,"name":136,"description":137,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Factorytalk Services Platform Security Vulnerabilities","Security vulnerabilities affecting Factorytalk Services Platform by Rockwellautomation",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":139,"apiVersion":140},"2026-10-18T14:15:56.348Z","3.0",[],{"rows":143,"total":11,"capped":17,"failed":16},[144],{"cveId":54,"name":115,"severity":59,"cvss":57,"added":116,"epss":60,"published":145,"ranges":146,"checked":4,"hits":148,"covers":17},"2021-03-03T18:15:14.643",[147],"2.10 and later",[]]