[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fHHiDQAb3sfeGkuD2cSvGZcqrhubpx4h0soh7ts1FNaI":3,"g5a-ex:schneider-electric\u002F140cpu65160s_firmware@*":95,"g5a-family:schneider-electric\u002F140cpu65160s_firmware":97},{"success":4,"data":5},true,{"product":6,"versions":20,"topVulnerabilitiesByEpss":23,"kevVulnerabilities":72,"seoMetadata":73,"meta":92},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":19},"schneider-electric","140cpu65160s_firmware",2,11,0,"2020-03-23",[14,17],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"3.52",false,{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},"3.60","140cpu65160s Firmware by Schneider-electric is a technology product with 2 tracked versions and 11 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[21,22],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},[24,32,38,42,46,53,56,60,64,68],{"cveId":25,"description":26,"publishedDate":27,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":16,"epssScore":31},"CVE-2018-7241","Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.","2018-04-18",9.8,"v3.0","Critical",0.03697,{"cveId":33,"description":34,"publishedDate":27,"cvssScore":35,"cvssVersion":29,"severity":36,"isKev":16,"epssScore":37},"CVE-2018-7240","A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.",8.8,"High",0.03201,{"cveId":39,"description":40,"publishedDate":27,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":16,"epssScore":41},"CVE-2018-7761","A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.",0.02098,{"cveId":43,"description":44,"publishedDate":27,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":16,"epssScore":45},"CVE-2018-7242","Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.",0.01884,{"cveId":47,"description":48,"publishedDate":49,"cvssScore":50,"cvssVersion":51,"severity":36,"isKev":16,"epssScore":52},"CVE-2019-6856","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP.","2020-01-06",7.5,"v3.1",0.0163,{"cveId":54,"description":55,"publishedDate":49,"cvssScore":50,"cvssVersion":51,"severity":36,"isKev":16,"epssScore":52},"CVE-2019-6857","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP.",{"cveId":57,"description":58,"publishedDate":27,"cvssScore":28,"cvssVersion":29,"severity":30,"isKev":16,"epssScore":59},"CVE-2018-7760","An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.",0.01469,{"cveId":61,"description":62,"publishedDate":49,"cvssScore":50,"cvssVersion":51,"severity":36,"isKev":16,"epssScore":63},"CVE-2018-7794","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP.",0.01399,{"cveId":65,"description":66,"publishedDate":12,"cvssScore":50,"cvssVersion":51,"severity":36,"isKev":16,"epssScore":67},"CVE-2020-7477","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions), and Premium processors with integrated Ethernet (all Versions), which could cause a Denial of Service when sending a specially crafted command over Modbus.",0.01321,{"cveId":69,"description":70,"publishedDate":27,"cvssScore":50,"cvssVersion":29,"severity":36,"isKev":16,"epssScore":71},"CVE-2018-7762","A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.",0.01291,[],{"title":74,"metaDescription":75,"keywords":76,"structuredData":77},"140cpu65160s Firmware by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for 140cpu65160s Firmware by Schneider-electric covering 2 versions with 11 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","140cpu65160s Firmware vulnerabilities, 140cpu65160s Firmware security, 140cpu65160s Firmware CVE, Schneider-electric 140cpu65160s Firmware, 140cpu65160s Firmware threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":78,"@type":79,"name":80,"description":75,"url":81,"manufacturer":82,"applicationCategory":86,"softwareVersion":87,"mainEntity":88},"https:\u002F\u002Fschema.org","SoftwareApplication","140cpu65160s Firmware","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002F140cpu65160s_firmware",{"@type":83,"name":84,"url":85},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","2 versions tracked",{"@type":89,"name":90,"description":91,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","140cpu65160s Firmware Security Vulnerabilities","Security vulnerabilities affecting 140cpu65160s Firmware by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":93,"apiVersion":94},"2026-10-19T05:38:08.150Z","3.0",{"rows":96,"total":11,"capped":16,"failed":11},[],[]]