[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fgb21bqCz8LsCq1uy9nyh9ny9HhtQfL9CRfPRAsfo7Jc":3,"g5a-ex:schneider-electric\u002Fecostruxure_process_expert@*":108,"g5a-family:schneider-electric\u002Fecostruxure_process_expert":110},{"success":4,"data":5},true,{"product":6,"versions":22,"topVulnerabilitiesByEpss":26,"kevVulnerabilities":85,"seoMetadata":86,"meta":105},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":21},"schneider-electric","ecostruxure_process_expert",3,14,0,"2024-02-14",[14,17,19],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"2020",false,{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},"2021",{"version":20,"cve_count":11,"kev_count":11,"has_kev":16},"2023","Ecostruxure Process Expert by Schneider-electric is a technology product with 3 tracked versions and 14 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[23,24,25],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},{"version":20,"cve_count":11,"kev_count":11,"has_kev":16},[27,35,42,47,52,58,65,70,75,80],{"cveId":28,"description":29,"publishedDate":30,"cvssScore":31,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":34},"CVE-2021-22797","A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)","2022-04-13",7.8,"v3.1","High",0.261,{"cveId":36,"description":37,"publishedDate":38,"cvssScore":39,"cvssVersion":32,"severity":40,"isKev":16,"epssScore":41},"CVE-2022-26507","A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer","2022-04-14",9.8,"Critical",0.02423,{"cveId":43,"description":44,"publishedDate":45,"cvssScore":39,"cvssVersion":32,"severity":40,"isKev":16,"epssScore":46},"CVE-2022-45789","A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\n\n","2023-01-31",0.01455,{"cveId":48,"description":49,"publishedDate":50,"cvssScore":39,"cvssVersion":32,"severity":40,"isKev":16,"epssScore":51},"CVE-2022-45788","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n","2023-01-30",0.01173,{"cveId":53,"description":54,"publishedDate":55,"cvssScore":56,"cvssVersion":32,"severity":40,"isKev":16,"epssScore":57},"CVE-2021-22779","Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.","2021-07-14",9.1,0.01051,{"cveId":59,"description":60,"publishedDate":61,"cvssScore":62,"cvssVersion":32,"severity":63,"isKev":16,"epssScore":64},"CVE-2022-24323","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)","2022-03-09",5.9,"Medium",0.0086,{"cveId":66,"description":67,"publishedDate":68,"cvssScore":39,"cvssVersion":32,"severity":40,"isKev":16,"epssScore":69},"CVE-2022-37300","A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).","2022-09-12",0.00768,{"cveId":71,"description":72,"publishedDate":12,"cvssScore":73,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":74},"CVE-2023-6408","\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n",8.1,0.00317,{"cveId":76,"description":77,"publishedDate":55,"cvssScore":78,"cvssVersion":32,"severity":63,"isKev":16,"epssScore":79},"CVE-2021-22781","Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.",5.5,0.00236,{"cveId":81,"description":82,"publishedDate":12,"cvssScore":83,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":84},"CVE-2023-6409","\nCWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized\naccess to a project file protected with application password when opening the file with\nEcoStruxure Control Expert.\n\n",7.7,0.0023,[],{"title":87,"metaDescription":88,"keywords":89,"structuredData":90},"Ecostruxure Process Expert by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Ecostruxure Process Expert by Schneider-electric covering 3 versions with 14 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Ecostruxure Process Expert vulnerabilities, Ecostruxure Process Expert security, Ecostruxure Process Expert CVE, Schneider-electric Ecostruxure Process Expert, Ecostruxure Process Expert threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":91,"@type":92,"name":93,"description":88,"url":94,"manufacturer":95,"applicationCategory":99,"softwareVersion":100,"mainEntity":101},"https:\u002F\u002Fschema.org","SoftwareApplication","Ecostruxure Process Expert","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fecostruxure_process_expert",{"@type":96,"name":97,"url":98},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","3 versions tracked",{"@type":102,"name":103,"description":104,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Ecostruxure Process Expert Security Vulnerabilities","Security vulnerabilities affecting Ecostruxure Process Expert by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":106,"apiVersion":107},"2026-10-19T03:02:18.257Z","3.0",{"rows":109,"total":11,"capped":16,"failed":11},[],[]]