[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fMVr7xEhIvbNxAhi-e6krfNRG8vbPNrkXrTS0M7Wsdeo":3,"g5a-ex:schneider-electric\u002Finteractive_graphical_scada_system_data_collector@*":70,"g5a-family:schneider-electric\u002Finteractive_graphical_scada_system_data_collector":72},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":47,"seoMetadata":48,"meta":67},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"schneider-electric","interactive_graphical_scada_system_data_collector",0,6,"2022-02-11",[],"Interactive Graphical Scada System Data Collector by Schneider-electric is a technology product and 6 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,24,29,35,39,43],{"cveId":17,"description":18,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":23},"CVE-2021-22823","A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)",9.1,"v3.1","Critical",false,0.21388,{"cveId":25,"description":26,"publishedDate":11,"cvssScore":27,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":28},"CVE-2021-22802","A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)",9.8,0.20165,{"cveId":30,"description":31,"publishedDate":11,"cvssScore":32,"cvssVersion":20,"severity":33,"isKev":22,"epssScore":34},"CVE-2021-22824","A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)",7.5,"High",0.14241,{"cveId":36,"description":37,"publishedDate":11,"cvssScore":27,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":38},"CVE-2021-22803","A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)",0.01943,{"cveId":40,"description":41,"publishedDate":11,"cvssScore":32,"cvssVersion":20,"severity":33,"isKev":22,"epssScore":42},"CVE-2021-22804","A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)",0.01294,{"cveId":44,"description":45,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":46},"CVE-2021-22805","A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)",0.0085,[],{"title":49,"metaDescription":50,"keywords":51,"structuredData":52},"Interactive Graphical Scada System Data Collector by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Interactive Graphical Scada System Data Collector by Schneider-electric with 6 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Interactive Graphical Scada System Data Collector vulnerabilities, Interactive Graphical Scada System Data Collector security, Interactive Graphical Scada System Data Collector CVE, Schneider-electric Interactive Graphical Scada System Data Collector, Interactive Graphical Scada System Data Collector threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":53,"@type":54,"name":55,"description":50,"url":56,"manufacturer":57,"applicationCategory":61,"softwareVersion":62,"mainEntity":63},"https:\u002F\u002Fschema.org","SoftwareApplication","Interactive Graphical Scada System Data Collector","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Finteractive_graphical_scada_system_data_collector",{"@type":58,"name":59,"url":60},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","Multiple versions",{"@type":64,"name":65,"description":66,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Interactive Graphical Scada System Data Collector Security Vulnerabilities","Security vulnerabilities affecting Interactive Graphical Scada System Data Collector by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":68,"apiVersion":69},"2026-10-20T07:11:54.449Z","3.0",{"rows":71,"total":9,"capped":22,"failed":9},[],[]]