[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fbFw7ZAbsUeD2pKPL6JgfQe6Xb25uzcqNArORoLDeMHw":3,"g5a-ex:schneider-electric\u002Finteractive_graphical_scada_system_data_server@*":77,"g5a-family:schneider-electric\u002Finteractive_graphical_scada_system_data_server":79},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":54,"seoMetadata":55,"meta":74},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"schneider-electric","interactive_graphical_scada_system_data_server",0,8,"2022-02-09",[],"Interactive Graphical Scada System Data Server by Schneider-electric is a technology product and 8 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,24,30,34,38,42,46,50],{"cveId":17,"description":18,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":23},"CVE-2022-24313","A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",9.8,"v3.1","Critical",false,0.44559,{"cveId":25,"description":26,"publishedDate":11,"cvssScore":27,"cvssVersion":20,"severity":28,"isKev":22,"epssScore":29},"CVE-2022-24315","A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",7.5,"High",0.19255,{"cveId":31,"description":32,"publishedDate":11,"cvssScore":27,"cvssVersion":20,"severity":28,"isKev":22,"epssScore":33},"CVE-2022-24314","A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",0.18178,{"cveId":35,"description":36,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":37},"CVE-2022-24311","A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",0.03505,{"cveId":39,"description":40,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":41},"CVE-2022-24312","A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data Server potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",0.03463,{"cveId":43,"description":44,"publishedDate":11,"cvssScore":19,"cvssVersion":20,"severity":21,"isKev":22,"epssScore":45},"CVE-2022-24310","A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",0.02227,{"cveId":47,"description":48,"publishedDate":11,"cvssScore":27,"cvssVersion":20,"severity":28,"isKev":22,"epssScore":49},"CVE-2022-24316","A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",0.01273,{"cveId":51,"description":52,"publishedDate":11,"cvssScore":27,"cvssVersion":20,"severity":28,"isKev":22,"epssScore":53},"CVE-2022-24317","A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)",0.01206,[],{"title":56,"metaDescription":57,"keywords":58,"structuredData":59},"Interactive Graphical Scada System Data Server by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Interactive Graphical Scada System Data Server by Schneider-electric with 8 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Interactive Graphical Scada System Data Server vulnerabilities, Interactive Graphical Scada System Data Server security, Interactive Graphical Scada System Data Server CVE, Schneider-electric Interactive Graphical Scada System Data Server, Interactive Graphical Scada System Data Server threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":60,"@type":61,"name":62,"description":57,"url":63,"manufacturer":64,"applicationCategory":68,"softwareVersion":69,"mainEntity":70},"https:\u002F\u002Fschema.org","SoftwareApplication","Interactive Graphical Scada System Data Server","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Finteractive_graphical_scada_system_data_server",{"@type":65,"name":66,"url":67},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","Multiple versions",{"@type":71,"name":72,"description":73,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Interactive Graphical Scada System Data Server Security Vulnerabilities","Security vulnerabilities affecting Interactive Graphical Scada System Data Server by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":75,"apiVersion":76},"2026-10-17T16:10:32.040Z","3.0",{"rows":78,"total":9,"capped":22,"failed":9},[],[]]