[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fz0241PUEe2TS6mJqWcq_aaytZFcuZZWflgSt4wy-umI":3,"g5a-ex:schneider-electric\u002Fmodicon_m340@*":113,"g5a-family:schneider-electric\u002Fmodicon_m340":115},{"success":4,"data":5},true,{"product":6,"versions":29,"topVulnerabilitiesByEpss":36,"kevVulnerabilities":90,"seoMetadata":91,"meta":110},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":28},"schneider-electric","modicon_m340",6,41,0,"2024-06-12",[14,18,20,22,24,26],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"bmxnoc0401",1,false,{"version":19,"cve_count":16,"kev_count":11,"has_kev":17},"bmxnoe0100x",{"version":21,"cve_count":16,"kev_count":11,"has_kev":17},"bmxnoe0110x",{"version":23,"cve_count":16,"kev_count":11,"has_kev":17},"bmxnoe011xx",{"version":25,"cve_count":16,"kev_count":11,"has_kev":17},"bmxnoe01xx",{"version":27,"cve_count":16,"kev_count":11,"has_kev":17},"bmxp3420xx","Modicon M340 by Schneider-electric is a technology product with 6 tracked versions and 41 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[30,31,32,33,34,35],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":16,"kev_count":11,"has_kev":17},{"version":21,"cve_count":16,"kev_count":11,"has_kev":17},{"version":23,"cve_count":16,"kev_count":11,"has_kev":17},{"version":25,"cve_count":16,"kev_count":11,"has_kev":17},{"version":27,"cve_count":16,"kev_count":11,"has_kev":17},[37,45,49,56,62,66,73,78,82,86],{"cveId":38,"description":39,"publishedDate":40,"cvssScore":41,"cvssVersion":42,"severity":43,"isKev":17,"epssScore":44},"CVE-2018-7842","A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller.","2019-05-22",9.8,"v3.1","Critical",0.35039,{"cveId":46,"description":47,"publishedDate":40,"cvssScore":41,"cvssVersion":42,"severity":43,"isKev":17,"epssScore":48},"CVE-2018-7846","A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.",0.29575,{"cveId":50,"description":51,"publishedDate":52,"cvssScore":53,"cvssVersion":42,"severity":54,"isKev":17,"epssScore":55},"CVE-2019-6851","A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.","2019-10-29",7.5,"High",0.29117,{"cveId":57,"description":58,"publishedDate":52,"cvssScore":59,"cvssVersion":42,"severity":60,"isKev":17,"epssScore":61},"CVE-2019-6841","A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol.",4.9,"Medium",0.23717,{"cveId":63,"description":64,"publishedDate":40,"cvssScore":41,"cvssVersion":42,"severity":43,"isKev":17,"epssScore":65},"CVE-2019-6808","A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus.",0.08161,{"cveId":67,"description":68,"publishedDate":69,"cvssScore":70,"cvssVersion":71,"severity":60,"isKev":17,"epssScore":72},"CVE-2013-0663","Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.","2013-04-04",6.8,"v2",0.0596,{"cveId":74,"description":75,"publishedDate":69,"cvssScore":76,"cvssVersion":71,"severity":54,"isKev":17,"epssScore":77},"CVE-2013-0664","The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests.",8.5,0.03909,{"cveId":79,"description":80,"publishedDate":40,"cvssScore":41,"cvssVersion":42,"severity":43,"isKev":17,"epssScore":81},"CVE-2018-7847","A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service or potential code execution by overwriting configuration settings of the controller over Modbus.",0.03808,{"cveId":83,"description":84,"publishedDate":40,"cvssScore":53,"cvssVersion":42,"severity":54,"isKev":17,"epssScore":85},"CVE-2018-7852","A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus.",0.03614,{"cveId":87,"description":88,"publishedDate":40,"cvssScore":53,"cvssVersion":42,"severity":54,"isKev":17,"epssScore":89},"CVE-2018-7845","A CWE-125: Out-of-bounds Read vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of unexpected data from the controller when reading specific memory blocks in the controller over Modbus.",0.03413,[],{"title":92,"metaDescription":93,"keywords":94,"structuredData":95},"Modicon M340 by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Modicon M340 by Schneider-electric covering 6 versions with 41 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Modicon M340 vulnerabilities, Modicon M340 security, Modicon M340 CVE, Schneider-electric Modicon M340, Modicon M340 threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":96,"@type":97,"name":98,"description":93,"url":99,"manufacturer":100,"applicationCategory":104,"softwareVersion":105,"mainEntity":106},"https:\u002F\u002Fschema.org","SoftwareApplication","Modicon M340","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fmodicon_m340",{"@type":101,"name":102,"url":103},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","6 versions tracked",{"@type":107,"name":108,"description":109,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Modicon M340 Security Vulnerabilities","Security vulnerabilities affecting Modicon M340 by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":111,"apiVersion":112},"2026-10-17T11:58:55.762Z","3.0",{"rows":114,"total":11,"capped":17,"failed":11},[],[116,119,121,124,127,130,133,136,138,140,143,145],{"product":117,"cves":118},"modicon_m340_bmxp342020",39,{"product":120,"cves":118},"modicon_m340_firmware",{"product":122,"cves":123},"modicon_m340_bmxp341000",33,{"product":125,"cves":126},"modicon_m340_bmxp342020_firmware",32,{"product":128,"cves":129},"modicon_m340_bmxp3420302",31,{"product":131,"cves":132},"modicon_m340_bmxp3420302_firmware",28,{"product":134,"cves":135},"modicon_m340_bmxp3420102",27,{"product":137,"cves":135},"modicon_m340_bmxp342000",{"product":139,"cves":135},"modicon_m340_bmxp341000_firmware",{"product":141,"cves":142},"modicon_m340_bmxp342000_firmware",25,{"product":144,"cves":142},"modicon_m340_bmxp3420102_firmware",{"product":146,"cves":147},"modicon_m340_bmxp3420102cl",19]