[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fqTxlOaengWsstz_BL0kQgx8f9KEhBTaA7WXfeVs9l6Y":3,"g5a-ex:schneider-electric\u002Fmodicon_m580_bmeh584040c_firmware@*":91,"g5a-family:schneider-electric\u002Fmodicon_m580_bmeh584040c_firmware":93},{"success":4,"data":5},true,{"product":6,"versions":22,"topVulnerabilitiesByEpss":26,"kevVulnerabilities":68,"seoMetadata":69,"meta":88},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":21},"schneider-electric","modicon_m580_bmeh584040c_firmware",3,7,0,"2024-02-14",[14,17,19],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"3.20",false,{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},"4.02",{"version":20,"cve_count":11,"kev_count":11,"has_kev":16},"4.20","Modicon M580 Bmeh584040c Firmware by Schneider-electric is a technology product with 3 tracked versions and 7 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[23,24,25],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},{"version":20,"cve_count":11,"kev_count":11,"has_kev":16},[27,35,40,46,51,58,63],{"cveId":28,"description":29,"publishedDate":30,"cvssScore":31,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":34},"CVE-2022-45789","A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\n\n","2023-01-31",9.8,"v3.1","Critical",0.01455,{"cveId":36,"description":37,"publishedDate":38,"cvssScore":31,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":39},"CVE-2022-45788","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n","2023-01-30",0.01173,{"cveId":41,"description":42,"publishedDate":43,"cvssScore":44,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":45},"CVE-2021-22779","Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.","2021-07-14",9.1,0.01051,{"cveId":47,"description":48,"publishedDate":49,"cvssScore":31,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":50},"CVE-2022-37300","A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior).","2022-09-12",0.00768,{"cveId":52,"description":53,"publishedDate":54,"cvssScore":55,"cvssVersion":32,"severity":56,"isKev":16,"epssScore":57},"CVE-2022-37301","A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum\u002FPremium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)","2022-11-22",7.5,"High",0.00754,{"cveId":59,"description":60,"publishedDate":61,"cvssScore":55,"cvssVersion":32,"severity":56,"isKev":16,"epssScore":62},"CVE-2021-22786","A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)","2023-02-01",0.0063,{"cveId":64,"description":65,"publishedDate":12,"cvssScore":66,"cvssVersion":32,"severity":56,"isKev":16,"epssScore":67},"CVE-2023-6408","\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n",8.1,0.00317,[],{"title":70,"metaDescription":71,"keywords":72,"structuredData":73},"Modicon M580 Bmeh584040c Firmware by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Modicon M580 Bmeh584040c Firmware by Schneider-electric covering 3 versions with 7 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Modicon M580 Bmeh584040c Firmware vulnerabilities, Modicon M580 Bmeh584040c Firmware security, Modicon M580 Bmeh584040c Firmware CVE, Schneider-electric Modicon M580 Bmeh584040c Firmware, Modicon M580 Bmeh584040c Firmware threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":74,"@type":75,"name":76,"description":71,"url":77,"manufacturer":78,"applicationCategory":82,"softwareVersion":83,"mainEntity":84},"https:\u002F\u002Fschema.org","SoftwareApplication","Modicon M580 Bmeh584040c Firmware","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fmodicon_m580_bmeh584040c_firmware",{"@type":79,"name":80,"url":81},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","3 versions tracked",{"@type":85,"name":86,"description":87,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Modicon M580 Bmeh584040c Firmware Security Vulnerabilities","Security vulnerabilities affecting Modicon M580 Bmeh584040c Firmware by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":89,"apiVersion":90},"2026-10-19T06:46:37.855Z","3.0",{"rows":92,"total":11,"capped":16,"failed":11},[],[]]