[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fXkRyP-2aagZWOYwNpgduFg2lnyozBlcMQ5vmbf9AgA8":3,"g5a-ex:schneider-electric\u002Fmodicon_m580_bmep582020h@*":92,"g5a-family:schneider-electric\u002Fmodicon_m580_bmep582020h":94},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":69,"seoMetadata":70,"meta":89},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"schneider-electric","modicon_m580_bmep582020h",0,14,"2024-02-14",[],"Modicon M580 Bmep582020h by Schneider-electric is a technology product and 14 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,30,37,43,48,54,59,63,66],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2022-45789","A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)\n\n","2023-01-31",9.8,"v3.1","Critical",false,0.01455,{"cveId":26,"description":27,"publishedDate":28,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":29},"CVE-2022-45788","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n","2023-01-30",0.01173,{"cveId":31,"description":32,"publishedDate":33,"cvssScore":34,"cvssVersion":21,"severity":35,"isKev":23,"epssScore":36},"CVE-2018-7851","CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.","2019-05-22",6.5,"Medium",0.01167,{"cveId":38,"description":39,"publishedDate":33,"cvssScore":40,"cvssVersion":21,"severity":41,"isKev":23,"epssScore":42},"CVE-2019-6819","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware versions of Modicon Quantum and Modicon Premium.",7.5,"High",0.01129,{"cveId":44,"description":45,"publishedDate":46,"cvssScore":40,"cvssVersion":21,"severity":41,"isKev":23,"epssScore":47},"CVE-2018-7838","A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a data length greater than 1020 bytes. A power cycle is then needed to reactivate the FTP service.","2019-07-15",0.01116,{"cveId":49,"description":50,"publishedDate":51,"cvssScore":52,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":53},"CVE-2021-22779","Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.","2021-07-14",9.1,0.01051,{"cveId":55,"description":56,"publishedDate":57,"cvssScore":40,"cvssVersion":21,"severity":41,"isKev":23,"epssScore":58},"CVE-2021-22792","A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller \u002F simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).","2021-09-02",0.00937,{"cveId":60,"description":61,"publishedDate":57,"cvssScore":34,"cvssVersion":21,"severity":35,"isKev":23,"epssScore":62},"CVE-2021-22791","A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller \u002F simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).",0.00839,{"cveId":64,"description":65,"publishedDate":57,"cvssScore":34,"cvssVersion":21,"severity":35,"isKev":23,"epssScore":62},"CVE-2021-22789","A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller \u002F simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).",{"cveId":67,"description":68,"publishedDate":57,"cvssScore":34,"cvssVersion":21,"severity":35,"isKev":23,"epssScore":62},"CVE-2021-22790","A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller \u002F simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all versions), Modicon MC80 (part numbers BMKC80*, all versions), Modicon Momentum Ethernet CPU (part numbers 171CBU*, all versions), PLC Simulator for EcoStruxureª Control Expert, including all Unity Pro versions (former name of EcoStruxureª Control Expert, all versions), PLC Simulator for EcoStruxureª Process Expert including all HDCS versions (former name of EcoStruxureª Process Expert, all versions), Modicon Quantum CPU (part numbers 140CPU*, all versions), Modicon Premium CPU (part numbers TSXP5*, all versions).",[],{"title":71,"metaDescription":72,"keywords":73,"structuredData":74},"Modicon M580 Bmep582020h by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Modicon M580 Bmep582020h by Schneider-electric with 14 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Modicon M580 Bmep582020h vulnerabilities, Modicon M580 Bmep582020h security, Modicon M580 Bmep582020h CVE, Schneider-electric Modicon M580 Bmep582020h, Modicon M580 Bmep582020h threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":75,"@type":76,"name":77,"description":72,"url":78,"manufacturer":79,"applicationCategory":83,"softwareVersion":84,"mainEntity":85},"https:\u002F\u002Fschema.org","SoftwareApplication","Modicon M580 Bmep582020h","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fmodicon_m580_bmep582020h",{"@type":80,"name":81,"url":82},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","Multiple versions",{"@type":86,"name":87,"description":88,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Modicon M580 Bmep582020h Security Vulnerabilities","Security vulnerabilities affecting Modicon M580 Bmep582020h by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":90,"apiVersion":91},"2026-10-19T05:15:52.133Z","3.0",{"rows":93,"total":9,"capped":23,"failed":9},[],[95],{"product":96,"cves":97},"modicon_m580_bmep582020h_firmware",7]