[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fbYiHf-wNg2qvcrNX3QZWoyMw5BBVAfpSZtKCNUuDJ9k":3,"g5a-ex:schneider-electric\u002Fmodicon_mc80_bmkc8020301_firmware@*":69,"g5a-family:schneider-electric\u002Fmodicon_mc80_bmkc8020301_firmware":71},{"success":4,"data":5},true,{"product":6,"versions":18,"topVulnerabilitiesByEpss":20,"kevVulnerabilities":46,"seoMetadata":47,"meta":66},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":17},"schneider-electric","modicon_mc80_bmkc8020301_firmware",1,4,0,"2024-02-14",[14],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"1.70",false,"Modicon Mc80 Bmkc8020301 Firmware by Schneider-electric is a technology product with 1 tracked version and 4 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[19],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},[21,29,36,41],{"cveId":22,"description":23,"publishedDate":24,"cvssScore":25,"cvssVersion":26,"severity":27,"isKev":16,"epssScore":28},"CVE-2022-45788","A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions), Modicon Momentum Unity M1E Processor - 171CBU* (All Versions), Modicon MC80 - BMKC80 (All Versions), Legacy Modicon Quantum - 140CPU65* and Premium CPUs - TSXP57* (All Versions)\n\n","2023-01-30",9.8,"v3.1","Critical",0.01173,{"cveId":30,"description":31,"publishedDate":32,"cvssScore":33,"cvssVersion":26,"severity":34,"isKev":16,"epssScore":35},"CVE-2022-37301","A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34*)(V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*)(V3.22 and prior), Legacy Modicon Quantum\u002FPremium(All Versions), Modicon Momentum MDI (171CBU*)(All Versions), Modicon MC80 (BMKC80)(V1.7 and prior)","2022-11-22",7.5,"High",0.00754,{"cveId":37,"description":38,"publishedDate":39,"cvssScore":33,"cvssVersion":26,"severity":34,"isKev":16,"epssScore":40},"CVE-2021-22786","A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions)","2023-02-01",0.0063,{"cveId":42,"description":43,"publishedDate":12,"cvssScore":44,"cvssVersion":26,"severity":34,"isKev":16,"epssScore":45},"CVE-2023-6408","\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n",8.1,0.00317,[],{"title":48,"metaDescription":49,"keywords":50,"structuredData":51},"Modicon Mc80 Bmkc8020301 Firmware by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Modicon Mc80 Bmkc8020301 Firmware by Schneider-electric covering 1 version with 4 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Modicon Mc80 Bmkc8020301 Firmware vulnerabilities, Modicon Mc80 Bmkc8020301 Firmware security, Modicon Mc80 Bmkc8020301 Firmware CVE, Schneider-electric Modicon Mc80 Bmkc8020301 Firmware, Modicon Mc80 Bmkc8020301 Firmware threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":52,"@type":53,"name":54,"description":49,"url":55,"manufacturer":56,"applicationCategory":60,"softwareVersion":61,"mainEntity":62},"https:\u002F\u002Fschema.org","SoftwareApplication","Modicon Mc80 Bmkc8020301 Firmware","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fmodicon_mc80_bmkc8020301_firmware",{"@type":57,"name":58,"url":59},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","1 versions tracked",{"@type":63,"name":64,"description":65,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Modicon Mc80 Bmkc8020301 Firmware Security Vulnerabilities","Security vulnerabilities affecting Modicon Mc80 Bmkc8020301 Firmware by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":67,"apiVersion":68},"2026-10-20T14:21:01.812Z","3.0",{"rows":70,"total":11,"capped":16,"failed":11},[],[]]