[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fIrNOiIi2DCdr8UWfHSSo3KQyanMFFwvyYWwUeWTOThw":3,"g5a-ex:schneider-electric\u002Fopc_factory_server@*":105,"g5a-family:schneider-electric\u002Fopc_factory_server":107},{"success":4,"data":5},true,{"product":6,"versions":36,"topVulnerabilitiesByEpss":46,"kevVulnerabilities":82,"seoMetadata":83,"meta":102},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":35},"schneider-electric","opc_factory_server",9,5,0,"2023-05-16",[14,18,21,23,25,27,29,31,33],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"3.34",1,false,{"version":19,"cve_count":20,"kev_count":11,"has_kev":17},"3.35",2,{"version":22,"cve_count":16,"kev_count":11,"has_kev":17},"3.5",{"version":24,"cve_count":11,"kev_count":11,"has_kev":17},"3.5.0",{"version":26,"cve_count":11,"kev_count":11,"has_kev":17},"3.50",{"version":28,"cve_count":11,"kev_count":11,"has_kev":17},"3.60",{"version":30,"cve_count":11,"kev_count":11,"has_kev":17},"3.61",{"version":32,"cve_count":11,"kev_count":11,"has_kev":17},"3.62",{"version":34,"cve_count":16,"kev_count":11,"has_kev":17},"3.63","Opc Factory Server by Schneider-electric is a technology product with 9 tracked versions and 5 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[37,38,39,40,41,42,43,44,45],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":20,"kev_count":11,"has_kev":17},{"version":22,"cve_count":16,"kev_count":11,"has_kev":17},{"version":24,"cve_count":11,"kev_count":11,"has_kev":17},{"version":26,"cve_count":11,"kev_count":11,"has_kev":17},{"version":28,"cve_count":11,"kev_count":11,"has_kev":17},{"version":30,"cve_count":11,"kev_count":11,"has_kev":17},{"version":32,"cve_count":11,"kev_count":11,"has_kev":17},{"version":34,"cve_count":16,"kev_count":11,"has_kev":17},[47,55,62,69,76],{"cveId":48,"description":49,"publishedDate":50,"cvssScore":51,"cvssVersion":52,"severity":53,"isKev":17,"epssScore":54},"CVE-2013-0662","Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.","2014-04-01",9.3,"v2","Critical",0.22217,{"cveId":56,"description":57,"publishedDate":58,"cvssScore":59,"cvssVersion":52,"severity":60,"isKev":17,"epssScore":61},"CVE-2011-3330","Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.","2011-11-04",7.2,"High",0.01302,{"cveId":63,"description":64,"publishedDate":65,"cvssScore":66,"cvssVersion":52,"severity":67,"isKev":17,"epssScore":68},"CVE-2014-0774","Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.","2014-02-28",6.8,"Medium",0.00467,{"cveId":70,"description":71,"publishedDate":72,"cvssScore":73,"cvssVersion":74,"severity":60,"isKev":17,"epssScore":75},"CVE-2015-1014","A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect\u002FCitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect\u002FCitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect\u002FCitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.","2019-03-25",7.3,"v3.0",0.00456,{"cveId":77,"description":78,"publishedDate":12,"cvssScore":79,"cvssVersion":80,"severity":67,"isKev":17,"epssScore":81},"CVE-2023-2161","\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause unauthorized read access to the file system when a malicious configuration file is\nloaded on to the software by a local user. ",5.5,"v3.1",0.0017,[],{"title":84,"metaDescription":85,"keywords":86,"structuredData":87},"Opc Factory Server by Schneider-electric - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Opc Factory Server by Schneider-electric covering 9 versions with 5 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Opc Factory Server vulnerabilities, Opc Factory Server security, Opc Factory Server CVE, Schneider-electric Opc Factory Server, Opc Factory Server threat intelligence, Schneider-electric security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":88,"@type":89,"name":90,"description":85,"url":91,"manufacturer":92,"applicationCategory":96,"softwareVersion":97,"mainEntity":98},"https:\u002F\u002Fschema.org","SoftwareApplication","Opc Factory Server","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fschneider-electric\u002Fopc_factory_server",{"@type":93,"name":94,"url":95},"Organization","Schneider-electric","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fschneider-electric","Security Software","9 versions tracked",{"@type":99,"name":100,"description":101,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Opc Factory Server Security Vulnerabilities","Security vulnerabilities affecting Opc Factory Server by Schneider-electric",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":103,"apiVersion":104},"2026-10-19T05:57:54.193Z","3.0",{"rows":106,"total":11,"capped":17,"failed":11},[],[108,110,112,114,116],{"product":109,"cves":16},"opc_factory_server_tlxcdlfofs",{"product":111,"cves":16},"opc_factory_server_tlxcdltofs",{"product":113,"cves":16},"opc_factory_server_tlxcdluofs",{"product":115,"cves":16},"opc_factory_server_tlxcdstofs",{"product":117,"cves":16},"opc_factory_server_tlxcdsuofs"]