[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fZ3al5E3i1Mus1Xe8Fs-0-IGcg_F2gT6zQr2kyDVIRlM":3,"g5a-ex:siemens\u002Fscalance_xf-200@*":72,"g5a-family:siemens\u002Fscalance_xf-200":74},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":49,"seoMetadata":50,"meta":69},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"siemens","scalance_xf-200",0,5,"2020-04-14",[],"Scalance Xf-200 by Siemens is a technology product and 5 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,32,36,43],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2013-5709","The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value.","2013-09-17",8.3,"v2","High",false,0.02988,{"cveId":26,"description":27,"publishedDate":28,"cvssScore":29,"cvssVersion":30,"severity":22,"isKev":23,"epssScore":31},"CVE-2019-13946","Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device.","2020-02-11",7.5,"v3.1",0.0146,{"cveId":33,"description":34,"publishedDate":11,"cvssScore":29,"cvssVersion":30,"severity":22,"isKev":23,"epssScore":35},"CVE-2019-19301","A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.",0.01361,{"cveId":37,"description":38,"publishedDate":39,"cvssScore":40,"cvssVersion":30,"severity":41,"isKev":23,"epssScore":42},"CVE-2019-6569","The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.","2019-03-26",9.1,"Critical",0.01328,{"cveId":44,"description":45,"publishedDate":28,"cvssScore":46,"cvssVersion":30,"severity":47,"isKev":23,"epssScore":48},"CVE-2019-13924","A vulnerability has been identified in SCALANCE S602 (All versions \u003C V4.1), SCALANCE S612 (All versions \u003C V4.1), SCALANCE S623 (All versions \u003C V4.1), SCALANCE S627-2M (All versions \u003C V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003C 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003C V5.5.0), SCALANCE X-200RNA switch family (All versions \u003C V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003C 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.",5.4,"Medium",0.00825,[],{"title":51,"metaDescription":52,"keywords":53,"structuredData":54},"Scalance Xf-200 by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Scalance Xf-200 by Siemens with 5 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Scalance Xf-200 vulnerabilities, Scalance Xf-200 security, Scalance Xf-200 CVE, Siemens Scalance Xf-200, Scalance Xf-200 threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":55,"@type":56,"name":57,"description":52,"url":58,"manufacturer":59,"applicationCategory":63,"softwareVersion":64,"mainEntity":65},"https:\u002F\u002Fschema.org","SoftwareApplication","Scalance Xf-200","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fscalance_xf-200",{"@type":60,"name":61,"url":62},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","Multiple versions",{"@type":66,"name":67,"description":68,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Scalance Xf-200 Security Vulnerabilities","Security vulnerabilities affecting Scalance Xf-200 by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":70,"apiVersion":71},"2026-10-18T23:07:31.693Z","3.0",{"rows":73,"total":9,"capped":23,"failed":9},[],[75],{"product":76,"cves":77},"scalance_xf-200_firmware",4]