[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f_OX5qgSngkHxg32M96Q4UZKRkaf-cOYQDiB2yi52yt0":3,"g5a-ex:siemens\u002Fscalance_xm-400_firmware@*":75,"g5a-family:siemens\u002Fscalance_xm-400_firmware":77},{"success":4,"data":5},true,{"product":6,"versions":22,"topVulnerabilitiesByEpss":26,"kevVulnerabilities":52,"seoMetadata":53,"meta":72},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":21},"siemens","scalance_xm-400_firmware",3,4,0,"2021-05-12",[14,17,19],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},"6.0",false,{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},"6.2.3",{"version":20,"cve_count":11,"kev_count":11,"has_kev":16},"6.4","Scalance Xm-400 Firmware by Siemens is a technology product with 3 tracked versions and 4 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[23,24,25],{"version":15,"cve_count":11,"kev_count":11,"has_kev":16},{"version":18,"cve_count":11,"kev_count":11,"has_kev":16},{"version":20,"cve_count":11,"kev_count":11,"has_kev":16},[27,35,41,46],{"cveId":28,"description":29,"publishedDate":30,"cvssScore":31,"cvssVersion":32,"severity":33,"isKev":16,"epssScore":34},"CVE-2021-3449","An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).","2021-03-25",5.9,"v3.1","Medium",0.63542,{"cveId":36,"description":37,"publishedDate":12,"cvssScore":38,"cvssVersion":32,"severity":39,"isKev":16,"epssScore":40},"CVE-2020-28393","An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device on the SCALANCE XM-400, XR-500 (All versions prior to v6.4).",7.5,"High",0.01629,{"cveId":42,"description":43,"publishedDate":44,"cvssScore":38,"cvssVersion":32,"severity":39,"isKev":16,"epssScore":45},"CVE-2019-13946","Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device.","2020-02-11",0.0146,{"cveId":47,"description":48,"publishedDate":49,"cvssScore":50,"cvssVersion":32,"severity":39,"isKev":16,"epssScore":51},"CVE-2017-12736","After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions.\r\n\r\nThis could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.","2017-12-26",8.8,0.01066,[],{"title":54,"metaDescription":55,"keywords":56,"structuredData":57},"Scalance Xm-400 Firmware by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Scalance Xm-400 Firmware by Siemens covering 3 versions with 4 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Scalance Xm-400 Firmware vulnerabilities, Scalance Xm-400 Firmware security, Scalance Xm-400 Firmware CVE, Siemens Scalance Xm-400 Firmware, Scalance Xm-400 Firmware threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":58,"@type":59,"name":60,"description":55,"url":61,"manufacturer":62,"applicationCategory":66,"softwareVersion":67,"mainEntity":68},"https:\u002F\u002Fschema.org","SoftwareApplication","Scalance Xm-400 Firmware","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fscalance_xm-400_firmware",{"@type":63,"name":64,"url":65},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","3 versions tracked",{"@type":69,"name":70,"description":71,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Scalance Xm-400 Firmware Security Vulnerabilities","Security vulnerabilities affecting Scalance Xm-400 Firmware by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":73,"apiVersion":74},"2026-10-19T00:12:37.202Z","3.0",{"rows":76,"total":11,"capped":16,"failed":11},[],[]]