[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fjuE3d-0KSRZOYWcpj-UhAAmTc408t2qu0SXIDJo839M":3,"g5a-ex:siemens\u002Fscalance_xp-200@*":97,"g5a-family:siemens\u002Fscalance_xp-200":99},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":74,"seoMetadata":75,"meta":94},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"siemens","scalance_xp-200",0,12,"2022-08-10",[],"Scalance Xp-200 by Siemens is a technology product and 12 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,32,38,42,47,52,57,63,69],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2021-3449","An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).","2021-03-25",5.9,"v3.1","Medium",false,0.63542,{"cveId":26,"description":27,"publishedDate":28,"cvssScore":29,"cvssVersion":21,"severity":30,"isKev":23,"epssScore":31},"CVE-2020-28400","Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.","2021-07-13",7.5,"High",0.01856,{"cveId":33,"description":34,"publishedDate":11,"cvssScore":35,"cvssVersion":21,"severity":36,"isKev":23,"epssScore":37},"CVE-2022-36323","Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",9.1,"Critical",0.01828,{"cveId":39,"description":40,"publishedDate":11,"cvssScore":29,"cvssVersion":21,"severity":30,"isKev":23,"epssScore":41},"CVE-2022-36324","Affected devices do not properly handle the renegotiation of SSL\u002FTLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",0.01744,{"cveId":43,"description":44,"publishedDate":45,"cvssScore":29,"cvssVersion":21,"severity":30,"isKev":23,"epssScore":46},"CVE-2019-13946","Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device.","2020-02-11",0.0146,{"cveId":48,"description":49,"publishedDate":50,"cvssScore":29,"cvssVersion":21,"severity":30,"isKev":23,"epssScore":51},"CVE-2019-19301","A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC\u002F60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.","2020-04-14",0.01361,{"cveId":53,"description":54,"publishedDate":55,"cvssScore":35,"cvssVersion":21,"severity":36,"isKev":23,"epssScore":56},"CVE-2019-6569","The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.","2019-03-26",0.01328,{"cveId":58,"description":59,"publishedDate":60,"cvssScore":61,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":62},"CVE-2019-10927","A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22\u002Ftcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device.","2019-08-13",6.5,0.01168,{"cveId":64,"description":65,"publishedDate":66,"cvssScore":67,"cvssVersion":21,"severity":30,"isKev":23,"epssScore":68},"CVE-2017-12736","After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions.\r\n\r\nThis could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.","2017-12-26",8.8,0.01066,{"cveId":70,"description":71,"publishedDate":11,"cvssScore":72,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":73},"CVE-2022-36325","Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",4.8,0.00956,[],{"title":76,"metaDescription":77,"keywords":78,"structuredData":79},"Scalance Xp-200 by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Scalance Xp-200 by Siemens with 12 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Scalance Xp-200 vulnerabilities, Scalance Xp-200 security, Scalance Xp-200 CVE, Siemens Scalance Xp-200, Scalance Xp-200 threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":80,"@type":81,"name":82,"description":77,"url":83,"manufacturer":84,"applicationCategory":88,"softwareVersion":89,"mainEntity":90},"https:\u002F\u002Fschema.org","SoftwareApplication","Scalance Xp-200","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fscalance_xp-200",{"@type":85,"name":86,"url":87},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","Multiple versions",{"@type":91,"name":92,"description":93,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Scalance Xp-200 Security Vulnerabilities","Security vulnerabilities affecting Scalance Xp-200 by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":95,"apiVersion":96},"2026-10-18T22:33:58.448Z","3.0",{"rows":98,"total":9,"capped":23,"failed":9},[],[100],{"product":101,"cves":10},"scalance_xp-200_firmware"]