[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fru4Pjq-WiVh5lR7N1LQruzpAsxD3AojOPf70-2DvbDA":3,"g5a-ex:siemens\u002Fsimatic_cp_343-1_firmware@*":84,"g5a-family:siemens\u002Fsimatic_cp_343-1_firmware":86},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":61,"seoMetadata":62,"meta":81},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"siemens","simatic_cp_343-1_firmware",0,7,"2024-02-13",[],"Simatic Cp 343-1 Firmware by Siemens is a technology product and 7 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,33,41,46,51,55],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2015-8214","A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions \u003C V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions \u003C V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions \u003C V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions \u003C V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions \u003C V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE \u002F TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions \u003C V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003C V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions \u003C V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions \u003C V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102\u002FTCP) is available and the CPs' configuration was stored on their corresponding CPUs.","2015-11-27",9.7,"v2","Critical",false,0.0209,{"cveId":26,"description":27,"publishedDate":28,"cvssScore":29,"cvssVersion":30,"severity":31,"isKev":23,"epssScore":32},"CVE-2016-8672","A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions \u003C V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions \u003C V3.2.17), SIMATIC S7-300 PN\u002FDP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN\u002FDP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the \"secure\" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission.","2016-11-23",5.3,"v3.0","Medium",0.01892,{"cveId":34,"description":35,"publishedDate":36,"cvssScore":37,"cvssVersion":38,"severity":39,"isKev":23,"epssScore":40},"CVE-2019-13946","Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device.","2020-02-11",7.5,"v3.1","High",0.0146,{"cveId":42,"description":43,"publishedDate":28,"cvssScore":44,"cvssVersion":30,"severity":39,"isKev":23,"epssScore":45},"CVE-2016-8673","A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions \u003C V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions \u003C V3.2.17), SIMATIC S7-300 PN\u002FDP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN\u002FDP CPU family (incl. SIPLUS variants) (All versions). The integrated web server at port 80\u002FTCP or port 443\u002FTCP of the affected devices could allow remote attackers to perform actions with the permissions of an authenticated user, provided the targeted user has an active session and is induced to trigger the malicious request.",8.8,0.01112,{"cveId":47,"description":48,"publishedDate":49,"cvssScore":37,"cvssVersion":38,"severity":39,"isKev":23,"epssScore":50},"CVE-2021-33737","A vulnerability has been identified in SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions \u003C V3.3), SIMATIC CP 443-1 (All versions \u003C V3.3), SIMATIC CP 443-1 Advanced (All versions \u003C V3.3), SIPLUS NET CP 443-1 (All versions \u003C V3.3), SIPLUS NET CP 443-1 Advanced (All versions \u003C V3.3). Sending a specially crafted packet to port 102\u002Ftcp of an affected device could cause a denial of service condition. A restart is needed to restore normal operations.","2021-09-14",0.01056,{"cveId":52,"description":53,"publishedDate":11,"cvssScore":37,"cvssVersion":38,"severity":39,"isKev":23,"epssScore":54},"CVE-2023-51440","A vulnerability has been identified in SIMATIC CP 343-1 (6GK7343-1EX30-0XE0) (All versions), SIMATIC CP 343-1 Lean (6GK7343-1CX10-0XE0) (All versions), SIPLUS NET CP 343-1 (6AG1343-1EX30-7XE0) (All versions), SIPLUS NET CP 343-1 Lean (6AG1343-1CX10-2XE0) (All versions). Affected products incorrectly validate TCP sequence numbers. This could allow an unauthenticated remote attacker to create a denial of service condition by injecting spoofed TCP RST packets.",0.00597,{"cveId":56,"description":57,"publishedDate":58,"cvssScore":59,"cvssVersion":38,"severity":31,"isKev":23,"epssScore":60},"CVE-2018-4843","A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 414F-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3),  SIMATIC S7-400 CPU 416F-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions \u003C V3.3), SIMATIC CP 443-1 (All versions \u003C V3.3), SIMATIC CP 443-1 Advanced (All versions \u003C V3.3), SIMATIC ET 200pro IM154-8 PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200pro IM154-8F PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200pro IM154-8FX PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200S IM151-8 PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC ET 200S IM151-8F PN\u002FDP CPU (All versions \u003C V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V1.7.0), SIMATIC S7-1500 Software Controller (All versions \u003C V1.7.0), SIMATIC S7-300 CPU 314C-2 PN\u002FDP (All versions \u003C V3.3.16), SIMATIC S7-300 CPU 315-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 315F-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 315T-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317F-2 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317T-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 319-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-300 CPU 319F-3 PN\u002FDP (All versions \u003C V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions \u003C V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003C V6.0.9), SIMATIC S7-400 PN\u002FDP V6 CPU family (incl. SIPLUS variants) (All versions \u003C V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions \u003C V8.1), SIMATIC WinAC RTX 2010 (All versions \u003C V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions \u003C V2010 SP3), SINUMERIK 828D (All versions \u003C V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN\u002FDP CPU (All versions \u003C V3.2.16), SIPLUS ET 200S IM151-8F PN\u002FDP CPU (All versions \u003C V3.2.16), SIPLUS NET CP 443-1 (All versions \u003C V3.3), SIPLUS NET CP 443-1 Advanced (All versions \u003C V3.3), SIPLUS S7-300 CPU 314C-2 PN\u002FDP (All versions \u003C V3.3.16), SIPLUS S7-300 CPU 315-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-300 CPU 315F-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-300 CPU 317-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-300 CPU 317F-2 PN\u002FDP (All versions \u003C V3.2.16), SIPLUS S7-400 CPU 414-3 PN\u002FDP V7 (All versions \u003C V7.0.3), SIPLUS S7-400 CPU 416-3 PN\u002FDP V7 (All versions \u003C V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system.\r\n\r\nThe security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system.","2018-03-20",6.5,0.00543,[],{"title":63,"metaDescription":64,"keywords":65,"structuredData":66},"Simatic Cp 343-1 Firmware by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Simatic Cp 343-1 Firmware by Siemens with 7 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic Cp 343-1 Firmware vulnerabilities, Simatic Cp 343-1 Firmware security, Simatic Cp 343-1 Firmware CVE, Siemens Simatic Cp 343-1 Firmware, Simatic Cp 343-1 Firmware threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":67,"@type":68,"name":69,"description":64,"url":70,"manufacturer":71,"applicationCategory":75,"softwareVersion":76,"mainEntity":77},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic Cp 343-1 Firmware","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_cp_343-1_firmware",{"@type":72,"name":73,"url":74},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","Multiple versions",{"@type":78,"name":79,"description":80,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Simatic Cp 343-1 Firmware Security Vulnerabilities","Security vulnerabilities affecting Simatic Cp 343-1 Firmware by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":82,"apiVersion":83},"2026-10-19T00:57:07.706Z","3.0",{"rows":85,"total":9,"capped":23,"failed":9},[],[]]