[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fQMeTySJSBii-D8VwLXo9OI-CWydYI6UV3RCkF8LSpEQ":3,"g5a-ex:siemens\u002Fsimatic_et_200sp_open_controller@*":54,"g5a-family:siemens\u002Fsimatic_et_200sp_open_controller":56},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":31,"seoMetadata":32,"meta":51},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"siemens","simatic_et_200sp_open_controller",0,2,"2021-06-09",[],"Simatic Et 200sp Open Controller by Siemens is a technology product and 2 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2020-15796","A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request.","2020-12-14",7.5,"v3.1","High",false,0.0161,{"cveId":26,"description":27,"publishedDate":11,"cvssScore":28,"cvssVersion":21,"severity":29,"isKev":23,"epssScore":30},"CVE-2020-24513","Domain-bypass transient execution vulnerability in some Intel Atom(R) Processors may allow an authenticated user to potentially enable information disclosure via local access.",6.5,"Medium",0.00472,[],{"title":33,"metaDescription":34,"keywords":35,"structuredData":36},"Simatic Et 200sp Open Controller by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Simatic Et 200sp Open Controller by Siemens with 2 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic Et 200sp Open Controller vulnerabilities, Simatic Et 200sp Open Controller security, Simatic Et 200sp Open Controller CVE, Siemens Simatic Et 200sp Open Controller, Simatic Et 200sp Open Controller threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":37,"@type":38,"name":39,"description":34,"url":40,"manufacturer":41,"applicationCategory":45,"softwareVersion":46,"mainEntity":47},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic Et 200sp Open Controller","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_et_200sp_open_controller",{"@type":42,"name":43,"url":44},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","Multiple versions",{"@type":48,"name":49,"description":50,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Simatic Et 200sp Open Controller Security Vulnerabilities","Security vulnerabilities affecting Simatic Et 200sp Open Controller by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":52,"apiVersion":53},"2026-10-19T00:20:21.814Z","3.0",{"rows":55,"total":9,"capped":23,"failed":9},[],[57,60,62,65,67,69,72],{"product":58,"cves":59},"simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware",7,{"product":61,"cves":59},"simatic_et_200sp_open_controller_cpu_1515sp_pc2",{"product":63,"cves":64},"simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware",3,{"product":66,"cves":64},"simatic_et_200sp_open_controller_cpu_1515sp_pc",{"product":68,"cves":10},"simatic_et_200sp_open_controller_firmware",{"product":70,"cves":71},"simatic_et_200sp_open_controller_cpu",1,{"product":73,"cves":71},"simatic_et_200sp_open_controller_cpu_firmware"]