[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f5MxbPImXPkT7rhXDrLeP4gGxlyAjFNh0M_ZwsH9rH2U":3,"g5a-ex:siemens\u002Fsimatic_s7-1500_cpu_1512sp-1@*":87,"g5a-family:siemens\u002Fsimatic_s7-1500_cpu_1512sp-1":89},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":64,"seoMetadata":65,"meta":84},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"siemens","simatic_s7-1500_cpu_1512sp-1",0,10,"2022-12-13",[],"Simatic S7-1500 Cpu 1512sp-1 by Siemens is a technology product and 10 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,29,32,36,41,43,47,53,59],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2021-37204","A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003C V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003C V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 \u003C V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003C V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 \u003C V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003C V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 \u003C V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003C V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 \u003C V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003C V2.3.6), TIM 1531 IRC (All versions \u003C V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102\u002Ftcp. A restart of the affected device is needed to restore normal operations.","2022-02-09",7.5,"v3.1","High",false,0.02181,{"cveId":26,"description":27,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":28},"CVE-2021-37185","A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 \u003C V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 \u003C V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 \u003C V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 \u003C V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003C V2.3.6), TIM 1531 IRC (All versions \u003C V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102\u002Ftcp. A restart of the affected device is needed to restore normal operations.",0.0206,{"cveId":30,"description":27,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":31},"CVE-2021-37205",0.0164,{"cveId":33,"description":34,"publishedDate":11,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":35},"CVE-2021-40365","Affected devices don't process correctly certain special crafted packets sent to port 102\u002Ftcp, which could allow an attacker to cause a denial of service in the device.",0.00929,{"cveId":37,"description":34,"publishedDate":11,"cvssScore":38,"cvssVersion":21,"severity":39,"isKev":23,"epssScore":40},"CVE-2021-44693",4.9,"Medium",0.00766,{"cveId":42,"description":34,"publishedDate":11,"cvssScore":38,"cvssVersion":21,"severity":39,"isKev":23,"epssScore":40},"CVE-2021-44695",{"cveId":44,"description":34,"publishedDate":11,"cvssScore":45,"cvssVersion":21,"severity":39,"isKev":23,"epssScore":46},"CVE-2021-44694",5.5,0.00658,{"cveId":48,"description":49,"publishedDate":50,"cvssScore":51,"cvssVersion":21,"severity":39,"isKev":23,"epssScore":52},"CVE-2022-30694","The login endpoint \u002FFormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.","2022-11-08",6.5,0.00324,{"cveId":54,"description":55,"publishedDate":56,"cvssScore":57,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":58},"CVE-2022-38465","A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003C V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003C V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003C V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003C V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003C V4.0), SINUMERIK MC (All versions \u003C V6.21), SINUMERIK ONE (All versions \u003C V6.21). Affected products  protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG\u002FPC and HMI communication.\r\n\r\nThis could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG\u002FPC and HMI communication.","2022-10-11",7.8,0.00241,{"cveId":60,"description":61,"publishedDate":62,"cvssScore":57,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":63},"CVE-2021-42029","A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003C V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003C V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.","2022-04-12",0.0024,[],{"title":66,"metaDescription":67,"keywords":68,"structuredData":69},"Simatic S7-1500 Cpu 1512sp-1 by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Simatic S7-1500 Cpu 1512sp-1 by Siemens with 10 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic S7-1500 Cpu 1512sp-1 vulnerabilities, Simatic S7-1500 Cpu 1512sp-1 security, Simatic S7-1500 Cpu 1512sp-1 CVE, Siemens Simatic S7-1500 Cpu 1512sp-1, Simatic S7-1500 Cpu 1512sp-1 threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":70,"@type":71,"name":72,"description":67,"url":73,"manufacturer":74,"applicationCategory":78,"softwareVersion":79,"mainEntity":80},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic S7-1500 Cpu 1512sp-1","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_s7-1500_cpu_1512sp-1",{"@type":75,"name":76,"url":77},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","Multiple versions",{"@type":81,"name":82,"description":83,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Simatic S7-1500 Cpu 1512sp-1 Security Vulnerabilities","Security vulnerabilities affecting Simatic S7-1500 Cpu 1512sp-1 by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":85,"apiVersion":86},"2026-10-18T20:58:21.747Z","3.0",{"rows":88,"total":9,"capped":23,"failed":9},[],[90,93,96],{"product":91,"cves":92},"simatic_s7-1500_cpu_1512sp-1_firmware",9,{"product":94,"cves":95},"simatic_s7-1500_cpu_1512sp-1_pn",3,{"product":97,"cves":95},"simatic_s7-1500_cpu_1512sp-1_pn_firmware"]