[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fph8nHC1F4SUcJ644CuOlqeLDNuBUJ3bxvZZT5mCa2IY":3,"g5a-ex:siemens\u002Fsimatic_s7-plcsim_advanced@*":100,"g5a-family:siemens\u002Fsimatic_s7-plcsim_advanced":102},{"success":4,"data":5},true,{"product":6,"versions":21,"topVulnerabilitiesByEpss":24,"kevVulnerabilities":77,"seoMetadata":78,"meta":97},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":20},"siemens","simatic_s7-plcsim_advanced",2,14,0,"2023-12-12",[14,18],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"2.0",1,false,{"version":19,"cve_count":11,"kev_count":11,"has_kev":17},"4.0","Simatic S7-plcsim Advanced by Siemens is a technology product with 2 tracked versions and 14 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[22,23],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":11,"kev_count":11,"has_kev":17},[25,33,40,44,47,52,56,61,68,73],{"cveId":26,"description":27,"publishedDate":28,"cvssScore":29,"cvssVersion":30,"severity":31,"isKev":17,"epssScore":32},"CVE-2020-15782","A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003C V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003C V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003C V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003C V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003C V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003C V6.15), SINUMERIK ONE (All versions \u003C V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102\u002Ftcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks.","2021-05-28",9.8,"v3.1","Critical",0.05184,{"cveId":34,"description":35,"publishedDate":36,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":39},"CVE-2021-37204","A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003C V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003C V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 \u003C V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003C V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 \u003C V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003C V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 \u003C V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003C V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 \u003C V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003C V2.3.6), TIM 1531 IRC (All versions \u003C V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102\u002Ftcp. A restart of the affected device is needed to restore normal operations.","2022-02-09",7.5,"High",0.02181,{"cveId":41,"description":42,"publishedDate":36,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":43},"CVE-2021-37185","A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 \u003C V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 \u003C V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 \u003C V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 \u003C V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 \u003C V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003C V2.3.6), TIM 1531 IRC (All versions \u003C V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102\u002Ftcp. A restart of the affected device is needed to restore normal operations.",0.0206,{"cveId":45,"description":42,"publishedDate":36,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":46},"CVE-2021-37205",0.0164,{"cveId":48,"description":49,"publishedDate":50,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":51},"CVE-2019-6568","The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device.","2019-04-17",0.01401,{"cveId":53,"description":54,"publishedDate":12,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":55},"CVE-2023-46156","Affected devices improperly handle specially crafted packets sent to port 102\u002Ftcp.\r\nThis could allow an attacker to create a denial of service condition. A restart is needed to restore\r\nnormal operations.",0.01244,{"cveId":57,"description":58,"publishedDate":59,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":60},"CVE-2023-28831","The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation.\r\n\r\nThis could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.","2023-09-12",0.01129,{"cveId":62,"description":63,"publishedDate":64,"cvssScore":65,"cvssVersion":30,"severity":66,"isKev":17,"epssScore":67},"CVE-2019-10929","A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003C V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003C V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003C V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003C V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003C V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003C V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003C V16), SIMATIC WinCC (TIA Portal) (All versions \u003C V16), SIMATIC WinCC OA (All versions \u003C V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003C V16), SIMATIC WinCC Runtime Professional (All versions \u003C V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003C V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102\u002Ftcp to the affected devices.","2019-08-13",5.9,"Medium",0.00978,{"cveId":69,"description":70,"publishedDate":71,"cvssScore":37,"cvssVersion":30,"severity":38,"isKev":17,"epssScore":72},"CVE-2021-40365","Affected devices don't process correctly certain special crafted packets sent to port 102\u002Ftcp, which could allow an attacker to cause a denial of service in the device.","2022-12-13",0.00929,{"cveId":74,"description":70,"publishedDate":71,"cvssScore":75,"cvssVersion":30,"severity":66,"isKev":17,"epssScore":76},"CVE-2021-44695",4.9,0.00766,[],{"title":79,"metaDescription":80,"keywords":81,"structuredData":82},"Simatic S7-plcsim Advanced by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Simatic S7-plcsim Advanced by Siemens covering 2 versions with 14 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic S7-plcsim Advanced vulnerabilities, Simatic S7-plcsim Advanced security, Simatic S7-plcsim Advanced CVE, Siemens Simatic S7-plcsim Advanced, Simatic S7-plcsim Advanced threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":83,"@type":84,"name":85,"description":80,"url":86,"manufacturer":87,"applicationCategory":91,"softwareVersion":92,"mainEntity":93},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic S7-plcsim Advanced","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_s7-plcsim_advanced",{"@type":88,"name":89,"url":90},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","2 versions tracked",{"@type":94,"name":95,"description":96,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Simatic S7-plcsim Advanced Security Vulnerabilities","Security vulnerabilities affecting Simatic S7-plcsim Advanced by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":98,"apiVersion":99},"2026-10-18T23:08:17.348Z","3.0",{"rows":101,"total":11,"capped":17,"failed":11},[],[103],{"product":104,"cves":105},"simatic_s7-plcsim_advanced_firmware",10]