[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f2Uxjj4yIkKpM0jnnidU_jvRtxcUJnQb4RQRS4gwllFI":3,"g5a-ex:siemens\u002Fsimatic_wincc_runtime_advanced@*":97,"g5a-family:siemens\u002Fsimatic_wincc_runtime_advanced":99},{"success":4,"data":5},true,{"product":6,"versions":22,"topVulnerabilitiesByEpss":25,"kevVulnerabilities":74,"seoMetadata":75,"meta":94},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":11,"lastCveUpdate":12,"versions":13,"description":21},"siemens","simatic_wincc_runtime_advanced",2,12,0,"2021-05-12",[14,18],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},"15.1",8,false,{"version":19,"cve_count":20,"kev_count":11,"has_kev":17},"16",7,"Simatic Wincc Runtime Advanced by Siemens is a technology product with 2 tracked versions and 12 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[23,24],{"version":15,"cve_count":16,"kev_count":11,"has_kev":17},{"version":19,"cve_count":20,"kev_count":11,"has_kev":17},[26,34,40,46,50,53,58,62,66,70],{"cveId":27,"description":28,"publishedDate":29,"cvssScore":30,"cvssVersion":31,"severity":32,"isKev":17,"epssScore":33},"CVE-2021-3449","An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).","2021-03-25",5.9,"v3.1","Medium",0.63542,{"cveId":35,"description":36,"publishedDate":12,"cvssScore":37,"cvssVersion":31,"severity":38,"isKev":17,"epssScore":39},"CVE-2021-27384","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",9.8,"Critical",0.02559,{"cveId":41,"description":42,"publishedDate":12,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":45},"CVE-2021-27385","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",7.5,"High",0.02555,{"cveId":47,"description":48,"publishedDate":12,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":49},"CVE-2021-27383","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",0.01792,{"cveId":51,"description":52,"publishedDate":12,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":49},"CVE-2021-27386","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",{"cveId":54,"description":55,"publishedDate":56,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":57},"CVE-2019-6575","A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003C V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (incl. SIPLUS variants) (All versions \u003C V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003C V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003C V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003C V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003C V1.1.0), SIMATIC RF600R family (All versions \u003C V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 \u003C V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003C V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003C V15.1 Upd 4), SINEC NMS (All versions \u003C V1.0 SP1), SINEMA Server (All versions \u003C V14 SP2), SINUMERIK OPC UA Server (All versions \u003C V2.1), TeleControl Server Basic (All versions \u003C V3.1.1). Specially crafted network packets sent to affected devices on port 4840\u002Ftcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.","2019-04-17",0.01646,{"cveId":59,"description":60,"publishedDate":12,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":61},"CVE-2021-25662","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.",0.0164,{"cveId":63,"description":64,"publishedDate":56,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":65},"CVE-2019-6568","The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device.",0.01401,{"cveId":67,"description":68,"publishedDate":12,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":69},"CVE-2021-25661","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition.",0.01148,{"cveId":71,"description":72,"publishedDate":12,"cvssScore":43,"cvssVersion":31,"severity":44,"isKev":17,"epssScore":73},"CVE-2021-25660","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.",0.00969,[],{"title":76,"metaDescription":77,"keywords":78,"structuredData":79},"Simatic Wincc Runtime Advanced by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Simatic Wincc Runtime Advanced by Siemens covering 2 versions with 12 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Simatic Wincc Runtime Advanced vulnerabilities, Simatic Wincc Runtime Advanced security, Simatic Wincc Runtime Advanced CVE, Siemens Simatic Wincc Runtime Advanced, Simatic Wincc Runtime Advanced threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":80,"@type":81,"name":82,"description":77,"url":83,"manufacturer":84,"applicationCategory":88,"softwareVersion":89,"mainEntity":90},"https:\u002F\u002Fschema.org","SoftwareApplication","Simatic Wincc Runtime Advanced","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsimatic_wincc_runtime_advanced",{"@type":85,"name":86,"url":87},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","2 versions tracked",{"@type":91,"name":92,"description":93,"vulnerabilityCount":10,"dateModified":12},"SecurityVulnerability","Simatic Wincc Runtime Advanced Security Vulnerabilities","Security vulnerabilities affecting Simatic Wincc Runtime Advanced by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":11,"lastUpdated":12,"generatedAt":95,"apiVersion":96},"2026-10-18T22:15:26.271Z","3.0",{"rows":98,"total":11,"capped":17,"failed":11},[],[]]