[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$foUOCbOhaxEVww4V-WpNuNB4Oo6S5bSIHKzjcnC0Ds-s":3,"g5a-ex:siemens\u002Fsinamics_gm150@*":85,"g5a-family:siemens\u002Fsinamics_gm150":87},{"success":4,"data":5},true,{"product":6,"versions":14,"topVulnerabilitiesByEpss":15,"kevVulnerabilities":62,"seoMetadata":63,"meta":82},{"vendorName":7,"productName":8,"versionCount":9,"totalCves":10,"kevCount":9,"lastCveUpdate":11,"versions":12,"description":13},"siemens","sinamics_gm150",0,9,"2021-05-12",[],"Sinamics Gm150 by Siemens is a technology product and 9 known security vulnerabilities. Get comprehensive security analysis, vulnerability tracking, and threat intelligence for this product.",[],[16,25,29,35,40,44,47,52,55],{"cveId":17,"description":18,"publishedDate":19,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":24},"CVE-2020-15798","A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003C V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003C V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)","2021-02-09",9.8,"v3.1","Critical",false,0.05218,{"cveId":26,"description":27,"publishedDate":11,"cvssScore":20,"cvssVersion":21,"severity":22,"isKev":23,"epssScore":28},"CVE-2021-27384","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.",0.02559,{"cveId":30,"description":31,"publishedDate":11,"cvssScore":32,"cvssVersion":21,"severity":33,"isKev":23,"epssScore":34},"CVE-2021-27385","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.",7.5,"High",0.02555,{"cveId":36,"description":37,"publishedDate":38,"cvssScore":32,"cvssVersion":21,"severity":33,"isKev":23,"epssScore":39},"CVE-2019-10936","Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition.","2019-10-10",0.02065,{"cveId":41,"description":42,"publishedDate":11,"cvssScore":32,"cvssVersion":21,"severity":33,"isKev":23,"epssScore":43},"CVE-2021-27386","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.",0.01792,{"cveId":45,"description":46,"publishedDate":11,"cvssScore":32,"cvssVersion":21,"severity":33,"isKev":23,"epssScore":43},"CVE-2021-27383","A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003C V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003C V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003C V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003C V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.",{"cveId":48,"description":49,"publishedDate":50,"cvssScore":32,"cvssVersion":21,"severity":33,"isKev":23,"epssScore":51},"CVE-2019-6568","The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device.","2019-04-17",0.01401,{"cveId":53,"description":54,"publishedDate":38,"cvssScore":32,"cvssVersion":21,"severity":33,"isKev":23,"epssScore":51},"CVE-2019-10923","An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.",{"cveId":56,"description":57,"publishedDate":58,"cvssScore":59,"cvssVersion":21,"severity":60,"isKev":23,"epssScore":61},"CVE-2017-2680","Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.","2017-05-11",6.5,"Medium",0.01149,[],{"title":64,"metaDescription":65,"keywords":66,"structuredData":67},"Sinamics Gm150 by Siemens - Security Vulnerabilities & Analysis | Precursor Intelligence","Comprehensive security analysis for Sinamics Gm150 by Siemens with 9 tracked vulnerabilities. Real-time threat intelligence, CVE tracking, and security recommendations.","Sinamics Gm150 vulnerabilities, Sinamics Gm150 security, Sinamics Gm150 CVE, Siemens Sinamics Gm150, Sinamics Gm150 threat intelligence, Siemens security, product security analysis, cybersecurity threats, vulnerability management, CVE tracking",{"@context":68,"@type":69,"name":70,"description":65,"url":71,"manufacturer":72,"applicationCategory":76,"softwareVersion":77,"mainEntity":78},"https:\u002F\u002Fschema.org","SoftwareApplication","Sinamics Gm150","https:\u002F\u002Fprecursorintelligence.com\u002Fvulnerabilities\u002Ftechnologies\u002Fvendors\u002Fsiemens\u002Fsinamics_gm150",{"@type":73,"name":74,"url":75},"Organization","Siemens","https:\u002F\u002Fprecursorintelligence.com\u002Fvendors\u002Fsiemens","Security Software","Multiple versions",{"@type":79,"name":80,"description":81,"vulnerabilityCount":10,"dateModified":11},"SecurityVulnerability","Sinamics Gm150 Security Vulnerabilities","Security vulnerabilities affecting Sinamics Gm150 by Siemens",{"totalVersions":9,"totalVulnerabilities":10,"kevVulnerabilities":9,"lastUpdated":11,"generatedAt":83,"apiVersion":84},"2026-10-19T02:32:07.526Z","3.0",{"rows":86,"total":9,"capped":23,"failed":9},[],[88],{"product":89,"cves":10},"sinamics_gm150_firmware"]