[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fsyO8iHoiKHTMYzScRBhCOoeJzXONVkRPSLM831citqU":3,"g5a-risk:CVE-2011-4875":223},{"success":4,"data":5,"meta":221},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":34,"epssPercentile":28,"epssTimeSeries":35,"severity":36,"affectedProducts":37,"affectedProductsCount":79,"references":80,"referencesCount":129,"weaknesses":130,"weaknessesCount":139,"isActivelyExploited":32,"cisaInfo":28,"otxData":28,"relatedBlogPosts":140,"seoMetadata":141,"configurations":166,"relatedVendorCves":212,"notableEvents":213},"CVE-2011-4875","What is CVE-2011-4875?","Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.","Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP...","2012-02-03T20:55:01.907","2026-06-16T23:35:33.427",9.3,"AV:N\u002FAC:M\u002FAu:N\u002FC:C\u002FI:C\u002FA:C",{"CVSSMetricV31":15,"CVSSMetricV30":16,"CVSSMetricV2":17,"CVSSMetricV40":33},[],[],[18],{"Source":19,"Type":20,"CVSSData":21,"BaseSeverity":29,"ExploitabilityScore":30,"ImpactScore":31,"ACInsufInfo":32,"ObtainAllPrivilege":32,"ObtainUserPrivilege":32,"ObtainOtherPrivilege":32,"UserInteractionRequired":32},"nvd@nist.gov","Primary",{"Version":22,"VectorString":13,"AccessVector":23,"AccessComplexity":24,"Authentication":25,"ConfidentialityImpact":26,"IntegrityImpact":26,"AvailabilityImpact":26,"BaseScore":12,"BaseSeverity":27,"Exploitability":28,"RemediationLevel":28,"ReportConfidence":28,"TemporalScore":28,"CollateralDamagePotential":28,"TargetDistribution":28,"ConfidentialityRequirement":28,"IntegrityRequirement":28,"AvailabilityRequirement":28,"EnvironmentalScore":28},"2.0","NETWORK","MEDIUM","NONE","COMPLETE","",null,"HIGH",8.6,10,false,[],0.13841,[34,34,34,34,34,34,34],"Critical",[38,43,46,49,52,56,60,63,66,69,72,75],{"vendor":39,"product":40,"version":41,"criteria":42,"vulnerable":4},"siemens","wincc_flexible","2004","cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*",{"vendor":39,"product":40,"version":44,"criteria":45,"vulnerable":4},"2005","cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*",{"vendor":39,"product":40,"version":47,"criteria":48,"vulnerable":4},"2007","cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*",{"vendor":39,"product":40,"version":50,"criteria":51,"vulnerable":4},"2008","cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*",{"vendor":39,"product":53,"version":54,"criteria":55,"vulnerable":4},"wincc","v11","cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*",{"vendor":39,"product":57,"version":58,"criteria":59,"vulnerable":4},"simatic_hmi_panels","comfort_panels","cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*",{"vendor":39,"product":57,"version":61,"criteria":62,"vulnerable":4},"mobile_panels","cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*",{"vendor":39,"product":57,"version":64,"criteria":65,"vulnerable":4},"mp","cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*",{"vendor":39,"product":57,"version":67,"criteria":68,"vulnerable":4},"op","cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*",{"vendor":39,"product":57,"version":70,"criteria":71,"vulnerable":4},"tp","cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*",{"vendor":39,"product":73,"version":54,"criteria":74,"vulnerable":4},"wincc_runtime_advanced","cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*",{"vendor":39,"product":76,"version":77,"criteria":78,"vulnerable":4},"wincc_flexible_runtime","*","cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*",12,[81,85,89,93,98,102,105,109,113,115,117,119,121,123,125,127],{"url":82,"source":83,"tags":84},"http:\u002F\u002Faluigi.org\u002Fadv\u002Fwinccflex_1-adv.txt","Aluigi",[],{"url":86,"source":87,"tags":88},"http:\u002F\u002Fwww.exploit-db.com\u002Fexploits\u002F18166","Exploit-db",[],{"url":90,"source":91,"tags":92},"http:\u002F\u002Fwww.osvdb.org\u002F77380","Osvdb",[],{"url":94,"source":95,"tags":96},"http:\u002F\u002Fwww.siemens.com\u002Fcorporate-technology\u002Fpool\u002Fde\u002Fforschungsfelder\u002Fsiemens_security_advisory_ssa-345442.pdf","Siemens",[97],"Vendor Advisory",{"url":99,"source":100,"tags":101},"http:\u002F\u002Fwww.us-cert.gov\u002Fcontrol_systems\u002Fpdf\u002FICS-ALERT-11-332-02.pdf","Us-cert",[],{"url":103,"source":100,"tags":104},"http:\u002F\u002Fwww.us-cert.gov\u002Fcontrol_systems\u002Fpdf\u002FICS-ALERT-11-332-02A.pdf",[],{"url":106,"source":100,"tags":107},"http:\u002F\u002Fwww.us-cert.gov\u002Fcontrol_systems\u002Fpdf\u002FICSA-12-030-01.pdf",[108],"US Government Resource",{"url":110,"source":111,"tags":112},"https:\u002F\u002Fexchange.xforce.ibmcloud.com\u002Fvulnerabilities\u002F71449","Ibmcloud",[],{"url":82,"source":83,"tags":114},[],{"url":86,"source":87,"tags":116},[],{"url":90,"source":91,"tags":118},[],{"url":94,"source":95,"tags":120},[97],{"url":99,"source":100,"tags":122},[],{"url":103,"source":100,"tags":124},[],{"url":106,"source":100,"tags":126},[108],{"url":110,"source":111,"tags":128},[],16,[131],{"id":132,"name":133,"description":134,"extendedDescription":135,"status":136,"abstraction":137,"structure":138},"CWE-119","Improper Restriction of Operations within the Bounds of a Memory Buffer","The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.","Certain languages allow direct addressing of memory locations and do not automatically ensure that these locations are valid for the memory buffer that is being referenced. This can cause read or write operations to be performed on memory locations that may be associated with other variables, data structures, or internal program data.","Stable","Class","Simple",1,[],{"title":142,"metaDescription":143,"keywords":144,"canonicalUrl":145,"structuredData":146},"What is CVE-2011-4875? Vulnerability Analysis | Security Advisory | Precursor Intelligence","Comprehensive analysis of CVE-2011-4875, a critical severity cyber security vulnerability from 2012. Stack-based buffer overflow in HmiLoad in the runtime lo...","CVE-2011-4875, CVE-2011-4875 vulnerability, CVE-2011-4875 security, critical severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2012, CVSS score, exploit, patch, remediation, siemens security, wincc_flexible vulnerability, wincc vulnerability, simatic_hmi_panels vulnerability","\u002Fwhat-is\u002Fcve-2011-4875",{"@context":147,"@type":148,"headline":142,"description":143,"datePublished":10,"dateModified":11,"author":149,"publisher":153,"about":157,"mainEntityOfPage":161,"articleSection":164,"keywords":165},"https:\u002F\u002Fschema.org","TechArticle",{"@type":150,"name":151,"url":152},"Organization","Precursor Intelligence","https:\u002F\u002Fprecursorintelligence.com",{"@type":150,"name":151,"url":152,"logo":154},{"@type":155,"url":156},"ImageObject","https:\u002F\u002Fprecursorintelligence.com\u002Fimg\u002Flogos\u002Feplogo.png",{"@type":158,"name":6,"description":159,"additionalType":160},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":162,"@id":163},"WebPage","https:\u002F\u002Fprecursorintelligence.com\u002Fwhat-is\u002Fcve-2011-4875","Cybersecurity","CVE-2011-4875, CVE-2011-4875 vulnerability, CVE-2011-4875 security, critical severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[167,180,186,200,206],{"Operator":28,"Negate":28,"Nodes":168},[169],{"Operator":170,"Negate":32,"CPEMatch":171},"OR",[172,174,176,178],{"Vulnerable":4,"Criteria":42,"MatchCriteriaID":173,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"7D596C29-36F8-44F2-897D-FD107769E5A9",{"Vulnerable":4,"Criteria":45,"MatchCriteriaID":175,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"2D84E29A-4BC2-4229-83C3-D9F7A641D19C",{"Vulnerable":4,"Criteria":48,"MatchCriteriaID":177,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"9B3ADDE1-1F91-43E7-A3C3-3069916F4B23",{"Vulnerable":4,"Criteria":51,"MatchCriteriaID":179,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"1432EC7A-47B2-41D1-B90B-72DBB79AC266",{"Operator":28,"Negate":28,"Nodes":181},[182],{"Operator":170,"Negate":32,"CPEMatch":183},[184],{"Vulnerable":4,"Criteria":55,"MatchCriteriaID":185,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"18A9883B-80E1-4B2E-88DA-D2326AE3DC08",{"Operator":28,"Negate":28,"Nodes":187},[188],{"Operator":170,"Negate":32,"CPEMatch":189},[190,192,194,196,198],{"Vulnerable":4,"Criteria":59,"MatchCriteriaID":191,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"DC593746-B329-43EA-8CA1-AA56AC5A3B10",{"Vulnerable":4,"Criteria":62,"MatchCriteriaID":193,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B",{"Vulnerable":4,"Criteria":65,"MatchCriteriaID":195,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"442AC914-BDD5-4D0C-9E04-88F60EE2B730",{"Vulnerable":4,"Criteria":68,"MatchCriteriaID":197,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"D9749966-1666-4F7D-90D0-17AFBB88AE83",{"Vulnerable":4,"Criteria":71,"MatchCriteriaID":199,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"9471D239-08B1-4076-82F7-2B73F4E343CE",{"Operator":28,"Negate":28,"Nodes":201},[202],{"Operator":170,"Negate":32,"CPEMatch":203},[204],{"Vulnerable":4,"Criteria":74,"MatchCriteriaID":205,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"1AE3AE80-C7A2-4581-993A-536936F6D315",{"Operator":28,"Negate":28,"Nodes":207},[208],{"Operator":170,"Negate":32,"CPEMatch":209},[210],{"Vulnerable":4,"Criteria":78,"MatchCriteriaID":211,"VersionStartExcluding":28,"VersionStartIncluding":28,"VersionEndExcluding":28,"VersionEndIncluding":28},"6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0",[],[214],{"id":215,"eventType":216,"eventTime":217,"details":218,"label":219,"color":220},"437d9fbd-ade0-43ea-b75a-bfd23623ace6","LOW_EPSS_DELTA","2026-06-16T04:06:53.103246+00:00","Daily EPSS score decreased by 0.264 on 2023-12-30","EPSS Score Decreased","green",{"lastModified":11,"cacheTime":222,"version":22},1792383440456,{"score":224,"band":225,"action":226,"scoredAt":227},54,"Medium","Plan remediation","2026-10-17T06:38:33.009887+00:00"]