[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fNXm6NrlB3hI75UHyGoeymfZrQMquCfwKr5gvUkQlkeE":3,"g5a-risk:CVE-2020-16218":119},{"success":4,"data":5,"meta":117},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":38,"epssPercentile":25,"epssTimeSeries":39,"severity":40,"affectedProducts":41,"affectedProductsCount":53,"references":54,"referencesCount":65,"weaknesses":66,"weaknessesCount":75,"isActivelyExploited":76,"cisaInfo":25,"otxData":25,"relatedBlogPosts":77,"seoMetadata":78,"configurations":103,"relatedVendorCves":115,"notableEvents":116},"CVE-2020-16218","What is CVE-2020-16218?","In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the \nsoftware does not neutralize or incorrectly neutralizes \nuser-controllable input before it is placed in output that is then used \nas a webpage and served to other users. Successful exploitation could \nlead to unauthorized access to patient data via a read-only web \napplication.","In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input befor...","2020-09-11T13:15:11.237","2023-12-12T21:15:07.627",3.5,"CVSS:3.1\u002FAV:A\u002FAC:L\u002FPR:L\u002FUI:N\u002FS:U\u002FC:L\u002FI:N\u002FA:N",{"CVSSMetricV31":15,"CVSSMetricV30":25,"CVSSMetricV2":28,"CVSSMetricV40":25},[16],{"Source":17,"Type":18,"CVSSData":19,"ExploitabilityScore":26,"ImpactScore":27},"nvd@nist.gov","Primary",{"Version":20,"VectorString":13,"AttackVector":21,"AttackComplexity":22,"PrivilegesRequired":22,"UserInteraction":23,"Scope":24,"ConfidentialityImpact":22,"IntegrityImpact":23,"AvailabilityImpact":23,"BaseScore":12,"BaseSeverity":22,"ExploitCodeMaturity":25,"RemediationLevel":25,"ReportConfidence":25,"TemporalScore":25,"TemporalSeverity":25,"ConfidentialityRequirement":25,"IntegrityRequirement":25,"AvailabilityRequirement":23,"ModifiedAttackVector":25,"ModifiedAttackComplexity":25,"ModifiedPrivilegesRequired":25,"ModifiedUserInteraction":25,"ModifiedScope":25,"ModifiedConfidentialityImpact":25,"ModifiedIntegrityImpact":25,"ModifiedAvailabilityImpact":25,"EnvironmentalScore":25,"EnvironmentalSeverity":25},"3.1","ADJACENT_NETWORK","LOW","NONE","UNCHANGED",null,2.1,1.4,[29],{"Source":17,"Type":18,"CVSSData":30,"BaseSeverity":22,"ExploitabilityScore":36,"ImpactScore":37,"ACInsufInfo":25,"ObtainAllPrivilege":25,"ObtainUserPrivilege":25,"ObtainOtherPrivilege":25,"UserInteractionRequired":4},{"Version":31,"VectorString":32,"AccessVector":21,"AccessComplexity":22,"Authentication":33,"ConfidentialityImpact":34,"IntegrityImpact":23,"AvailabilityImpact":23,"BaseScore":35,"BaseSeverity":25,"Exploitability":25,"RemediationLevel":25,"ReportConfidence":25,"TemporalScore":25,"CollateralDamagePotential":25,"TargetDistribution":25,"ConfidentialityRequirement":25,"IntegrityRequirement":25,"AvailabilityRequirement":25,"EnvironmentalScore":25},"2.0","AV:A\u002FAC:L\u002FAu:S\u002FC:P\u002FI:N\u002FA:N","SINGLE","PARTIAL",2.7,5.1,2.9,0.00653,[38,38,38,38,38,38,38],"Low",[42,47,50],{"vendor":43,"product":44,"version":45,"criteria":46,"vulnerable":4},"philips","patient_information_center_ix","b.02","cpe:2.3:a:philips:patient_information_center_ix:b.02:*:*:*:*:*:*:*",{"vendor":43,"product":44,"version":48,"criteria":49,"vulnerable":4},"c.02","cpe:2.3:a:philips:patient_information_center_ix:c.02:*:*:*:*:*:*:*",{"vendor":43,"product":44,"version":51,"criteria":52,"vulnerable":4},"c.03","cpe:2.3:a:philips:patient_information_center_ix:c.03:*:*:*:*:*:*:*",3,[55,61],{"url":56,"source":57,"tags":58},"https:\u002F\u002Fus-cert.cisa.gov\u002Fics\u002Fadvisories\u002Ficsma-20-254-01","CISA",[59,60],"Third Party Advisory","US Government Resource",{"url":62,"source":63,"tags":64},"https:\u002F\u002Fwww.philips.com\u002Fproductsecurity","Philips",[],2,[67],{"id":68,"name":69,"description":70,"extendedDescription":71,"status":72,"abstraction":73,"structure":74},"CWE-79","Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.","Cross-site scripting (XSS) vulnerabilities occur when:\nThere are three main kinds of XSS:\nOnce the malicious script is injected, the attacker can perform a variety of malicious activities. The attacker could transfer private information, such as cookies that may include session information, from the victim's machine to the attacker. The attacker could send malicious requests to a web site on behalf of the victim, which could be especially dangerous to the site if the victim has administrator privileges to manage that site. Phishing attacks could be used to emulate trusted web sites and trick the victim into entering a password, allowing the attacker to compromise the victim's account on that web site. Finally, the script could exploit a vulnerability in the web browser itself possibly taking over the victim's machine, sometimes referred to as \"drive-by hacking.\"\nIn many cases, the attack can be launched without the victim even being aware of it. Even with careful users, attackers frequently use a variety of methods to encode the malicious portion of the attack, such as URL encoding or Unicode, so the request looks less suspicious.","Stable","Base","Simple",1,false,[],{"title":79,"metaDescription":80,"keywords":81,"canonicalUrl":82,"structuredData":83},"What is CVE-2020-16218? Vulnerability Analysis | Security Advisory | Precursor Intelligence","Comprehensive analysis of CVE-2020-16218, a low severity cyber security vulnerability from 2020. In Patient Information Center iX (PICiX) Versions B.02, C.02...","CVE-2020-16218, CVE-2020-16218 vulnerability, CVE-2020-16218 security, low severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2020, CVSS score, exploit, patch, remediation, philips security, patient_information_center_ix vulnerability","\u002Fwhat-is\u002Fcve-2020-16218",{"@context":84,"@type":85,"headline":79,"description":80,"datePublished":10,"dateModified":11,"author":86,"publisher":90,"about":94,"mainEntityOfPage":98,"articleSection":101,"keywords":102},"https:\u002F\u002Fschema.org","TechArticle",{"@type":87,"name":88,"url":89},"Organization","Precursor Intelligence","https:\u002F\u002Fprecursorintelligence.com",{"@type":87,"name":88,"url":89,"logo":91},{"@type":92,"url":93},"ImageObject","https:\u002F\u002Fprecursorintelligence.com\u002Fimg\u002Flogos\u002Feplogo.png",{"@type":95,"name":6,"description":96,"additionalType":97},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":99,"@id":100},"WebPage","https:\u002F\u002Fprecursorintelligence.com\u002Fwhat-is\u002Fcve-2020-16218","Cybersecurity","CVE-2020-16218, CVE-2020-16218 vulnerability, CVE-2020-16218 security, low severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[104],{"Operator":25,"Negate":25,"Nodes":105},[106],{"Operator":107,"Negate":25,"CPEMatch":108},"OR",[109,111,113],{"Vulnerable":4,"Criteria":46,"MatchCriteriaID":110,"VersionStartExcluding":25,"VersionStartIncluding":25,"VersionEndExcluding":25,"VersionEndIncluding":25},"C4FA1FEC-5139-48C1-856C-8062436AE6C6",{"Vulnerable":4,"Criteria":49,"MatchCriteriaID":112,"VersionStartExcluding":25,"VersionStartIncluding":25,"VersionEndExcluding":25,"VersionEndIncluding":25},"F3220AB2-AC0D-4AC2-90D8-76C02FC693EB",{"Vulnerable":4,"Criteria":52,"MatchCriteriaID":114,"VersionStartExcluding":25,"VersionStartIncluding":25,"VersionEndExcluding":25,"VersionEndIncluding":25},"AE1FB3E9-E269-434A-B1C2-D54C40F437BE",[],[],{"lastModified":11,"cacheTime":118,"version":31},1792353301492,{"score":120,"band":121,"action":122,"scoredAt":123},14,"Info","Track","2026-10-16T06:49:21.802098+00:00"]