[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$fukZ5e6QogS46ZGnr9F5YbskuRLugLDX17JAi27VI4eU":3,"g5a-risk:CVE-2020-7592":170},{"success":4,"data":5,"meta":168},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":38,"epssPercentile":27,"epssTimeSeries":39,"severity":40,"affectedProducts":41,"affectedProductsCount":72,"references":73,"referencesCount":85,"weaknesses":86,"weaknessesCount":95,"isActivelyExploited":96,"cisaInfo":27,"otxData":27,"relatedBlogPosts":97,"seoMetadata":98,"configurations":123,"relatedVendorCves":166,"notableEvents":167},"CVE-2020-7592","What is CVE-2020-7592?","A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.","A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generatio...","2020-07-14T14:15:19.073","2020-07-22T13:56:04.357",6.5,"CVSS:3.1\u002FAV:A\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:H\u002FI:N\u002FA:N",{"CVSSMetricV31":15,"CVSSMetricV30":27,"CVSSMetricV2":30,"CVSSMetricV40":27},[16],{"Source":17,"Type":18,"CVSSData":19,"ExploitabilityScore":28,"ImpactScore":29},"nvd@nist.gov","Primary",{"Version":20,"VectorString":13,"AttackVector":21,"AttackComplexity":22,"PrivilegesRequired":23,"UserInteraction":23,"Scope":24,"ConfidentialityImpact":25,"IntegrityImpact":23,"AvailabilityImpact":23,"BaseScore":12,"BaseSeverity":26,"ExploitCodeMaturity":27,"RemediationLevel":27,"ReportConfidence":27,"TemporalScore":27,"TemporalSeverity":27,"ConfidentialityRequirement":27,"IntegrityRequirement":27,"AvailabilityRequirement":23,"ModifiedAttackVector":27,"ModifiedAttackComplexity":27,"ModifiedPrivilegesRequired":27,"ModifiedUserInteraction":27,"ModifiedScope":27,"ModifiedConfidentialityImpact":27,"ModifiedIntegrityImpact":27,"ModifiedAvailabilityImpact":27,"EnvironmentalScore":27,"EnvironmentalSeverity":27},"3.1","ADJACENT_NETWORK","LOW","NONE","UNCHANGED","HIGH","MEDIUM",null,2.8,3.6,[31],{"Source":17,"Type":18,"CVSSData":32,"BaseSeverity":22,"ExploitabilityScore":12,"ImpactScore":37,"ACInsufInfo":27,"ObtainAllPrivilege":27,"ObtainUserPrivilege":27,"ObtainOtherPrivilege":27,"UserInteractionRequired":27},{"Version":33,"VectorString":34,"AccessVector":21,"AccessComplexity":22,"Authentication":23,"ConfidentialityImpact":35,"IntegrityImpact":23,"AvailabilityImpact":23,"BaseScore":36,"BaseSeverity":27,"Exploitability":27,"RemediationLevel":27,"ReportConfidence":27,"TemporalScore":27,"CollateralDamagePotential":27,"TargetDistribution":27,"ConfidentialityRequirement":27,"IntegrityRequirement":27,"AvailabilityRequirement":27,"EnvironmentalScore":27},"2.0","AV:A\u002FAC:L\u002FAu:N\u002FC:P\u002FI:N\u002FA:N","PARTIAL",3.3,2.9,0.00332,[38,38,38,38,38,38,38],"Medium",[42,47,50,53,56,60,63,66,69],{"vendor":43,"product":44,"version":45,"criteria":46,"vulnerable":4},"siemens","simatic_hmi_basic_panels_1st_generation","*","cpe:2.3:a:siemens:simatic_hmi_basic_panels_1st_generation:*:*:*:*:*:*:*:*",{"vendor":43,"product":48,"version":45,"criteria":49,"vulnerable":4},"simatic_hmi_basic_panels_2nd_generation","cpe:2.3:a:siemens:simatic_hmi_basic_panels_2nd_generation:*:*:*:*:*:*:*:*",{"vendor":43,"product":51,"version":45,"criteria":52,"vulnerable":4},"simatic_wincc_runtime_advanced","cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",{"vendor":43,"product":54,"version":45,"criteria":55,"vulnerable":4},"simatic_hmi_comfort_panels_firmware","cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",{"vendor":43,"product":57,"version":58,"criteria":59,"vulnerable":4},"simatic_hmi_comfort_panels","-","cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",{"vendor":43,"product":61,"version":45,"criteria":62,"vulnerable":4},"simatic_hmi_ktp700f_mobile_arctic_firmware","cpe:2.3:o:siemens:simatic_hmi_ktp700f_mobile_arctic_firmware:*:*:*:*:*:*:*:*",{"vendor":43,"product":64,"version":58,"criteria":65,"vulnerable":4},"simatic_hmi_ktp700f_mobile_arctic","cpe:2.3:h:siemens:simatic_hmi_ktp700f_mobile_arctic:-:*:*:*:*:*:*:*",{"vendor":43,"product":67,"version":45,"criteria":68,"vulnerable":4},"simatic_hmi_mobile_panels_2nd_generation_firmware","cpe:2.3:o:siemens:simatic_hmi_mobile_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",{"vendor":43,"product":70,"version":58,"criteria":71,"vulnerable":4},"simatic_hmi_mobile_panels_2nd_generation","cpe:2.3:h:siemens:simatic_hmi_mobile_panels_2nd_generation:-:*:*:*:*:*:*:*",9,[74,79],{"url":75,"source":76,"tags":77},"https:\u002F\u002Fcert-portal.siemens.com\u002Fproductcert\u002Fpdf\u002Fssa-364335.pdf","Siemens",[78],"Vendor Advisory",{"url":80,"source":81,"tags":82},"https:\u002F\u002Fus-cert.cisa.gov\u002Fics\u002Fadvisories\u002Ficsa-20-196-04","CISA",[83,84],"Third Party Advisory","US Government Resource",2,[87],{"id":88,"name":89,"description":90,"extendedDescription":91,"status":92,"abstraction":93,"structure":94},"CWE-319","Cleartext Transmission of Sensitive Information","The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.","Many communication channels can be \"sniffed\" (monitored) by adversaries during data transmission. For example, in networking, packets can traverse many intermediary nodes from the source to the destination, whether across the internet, an internal network, the cloud, etc. Some actors might have privileged access to a network interface or any link along the channel, such as a router, but they might not be authorized to collect the underlying data. As a result, network traffic could be sniffed by adversaries, spilling security-critical data.\nApplicable communication channels are not limited to software products. Applicable channels include hardware-specific technologies such as internal hardware networks and external debug channels, supporting remote JTAG debugging. When mitigations are not applied to combat adversaries within the product's threat model, this weakness significantly lowers the difficulty of exploitation by such adversaries.\nWhen full communications are recorded or logged, such as with a packet dump, an adversary could attempt to obtain the dump long after the transmission has occurred and try to \"sniff\" the cleartext from the recorded communications in the dump itself. Even if the information is encoded in a way that is not human-readable, certain techniques could determine which encoding is being used, then decode the information.","Draft","Base","Simple",1,false,[],{"title":99,"metaDescription":100,"keywords":101,"canonicalUrl":102,"structuredData":103},"What is CVE-2020-7592? Vulnerability Analysis | Security Advisory | Precursor Intelligence","Comprehensive analysis of CVE-2020-7592, a medium severity cyber security vulnerability from 2020. A vulnerability has been identified in SIMATIC HMI Basic P...","CVE-2020-7592, CVE-2020-7592 vulnerability, CVE-2020-7592 security, medium severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2020, CVSS score, exploit, patch, remediation, siemens security, simatic_hmi_basic_panels_1st_generation vulnerability, simatic_hmi_basic_panels_2nd_generation vulnerability, simatic_wincc_runtime_advanced vulnerability, simatic_hmi_comfort_panels_firmware vulnerability, simatic_hmi_comfort_panels vulnerability","\u002Fwhat-is\u002Fcve-2020-7592",{"@context":104,"@type":105,"headline":99,"description":100,"datePublished":10,"dateModified":11,"author":106,"publisher":110,"about":114,"mainEntityOfPage":118,"articleSection":121,"keywords":122},"https:\u002F\u002Fschema.org","TechArticle",{"@type":107,"name":108,"url":109},"Organization","Precursor Intelligence","https:\u002F\u002Fprecursorintelligence.com",{"@type":107,"name":108,"url":109,"logo":111},{"@type":112,"url":113},"ImageObject","https:\u002F\u002Fprecursorintelligence.com\u002Fimg\u002Flogos\u002Feplogo.png",{"@type":115,"name":6,"description":116,"additionalType":117},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":119,"@id":120},"WebPage","https:\u002F\u002Fprecursorintelligence.com\u002Fwhat-is\u002Fcve-2020-7592","Cybersecurity","CVE-2020-7592, CVE-2020-7592 vulnerability, CVE-2020-7592 security, medium severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[124,135,146,156],{"Operator":27,"Negate":27,"Nodes":125},[126],{"Operator":127,"Negate":27,"CPEMatch":128},"OR",[129,131,133],{"Vulnerable":4,"Criteria":46,"MatchCriteriaID":130,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"CF9AA1D8-BDF6-40EC-8D04-49C5EAB39431",{"Vulnerable":4,"Criteria":49,"MatchCriteriaID":132,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"7E561873-49B4-4D85-8D40-9D33CEE7E7CE",{"Vulnerable":4,"Criteria":52,"MatchCriteriaID":134,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"79EE15DC-74D3-4551-AAD0-EA0CB600DA76",{"Operator":136,"Negate":27,"Nodes":137},"AND",[138,142],{"Operator":127,"Negate":27,"CPEMatch":139},[140],{"Vulnerable":4,"Criteria":55,"MatchCriteriaID":141,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"3C98A381-02D5-460E-8849-63F4576BC52C",{"Operator":127,"Negate":27,"CPEMatch":143},[144],{"Vulnerable":27,"Criteria":59,"MatchCriteriaID":145,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"3BCFE761-35C9-43EF-85BC-E8083B9F75CB",{"Operator":136,"Negate":27,"Nodes":147},[148,152],{"Operator":127,"Negate":27,"CPEMatch":149},[150],{"Vulnerable":4,"Criteria":62,"MatchCriteriaID":151,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"BAC6E895-5577-4047-B7CC-95398563984D",{"Operator":127,"Negate":27,"CPEMatch":153},[154],{"Vulnerable":27,"Criteria":65,"MatchCriteriaID":155,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"4631C615-B2A4-40C3-9D1A-A1AD3C64EC51",{"Operator":136,"Negate":27,"Nodes":157},[158,162],{"Operator":127,"Negate":27,"CPEMatch":159},[160],{"Vulnerable":4,"Criteria":68,"MatchCriteriaID":161,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"08693615-7A47-4062-A73D-7CDE359826F5",{"Operator":127,"Negate":27,"CPEMatch":163},[164],{"Vulnerable":27,"Criteria":71,"MatchCriteriaID":165,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":27,"VersionEndIncluding":27},"59D5490F-EACA-467F-89ED-988A45393EAC",[],[],{"lastModified":11,"cacheTime":169,"version":33},1792379873707,{"score":171,"band":172,"action":173,"scoredAt":174},21,"Low","Monitor","2026-10-16T06:48:59.133051+00:00"]