[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f4ENGIWBcYYXRApcTeLrLgAQuT0uW-p_l9ctv5-pzhb0":3,"g5a-risk:CVE-2022-40227":403},{"success":4,"data":5,"meta":400},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":29,"epssPercentile":26,"epssTimeSeries":30,"severity":31,"affectedProducts":32,"affectedProductsCount":117,"references":118,"referencesCount":124,"weaknesses":125,"weaknessesCount":124,"isActivelyExploited":134,"cisaInfo":26,"otxData":26,"relatedBlogPosts":135,"seoMetadata":136,"configurations":161,"relatedVendorCves":398,"notableEvents":399},"CVE-2022-40227","What is CVE-2022-40227?","A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003C V17 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003C V17 Update 4), SIMATIC HMI KTP1200 Basic (All versions \u003C V17 Update 5), SIMATIC HMI KTP400 Basic (All versions \u003C V17 Update 5), SIMATIC HMI KTP700 Basic (All versions \u003C V17 Update 5), SIMATIC HMI KTP900 Basic (All versions \u003C V17 Update 5), SIPLUS HMI KTP1200 BASIC (All versions \u003C V17 Update 5), SIPLUS HMI KTP400 BASIC (All versions \u003C V17 Update 5), SIPLUS HMI KTP700 BASIC (All versions \u003C V17 Update 5), SIPLUS HMI KTP900 BASIC (All versions \u003C V17 Update 5). Affected devices do not properly validate input sent to certain services over TCP. This could allow an unauthenticated remote attacker to cause a permanent denial of service condition (requiring a device reboot) by sending specially crafted TCP packets.","A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003C V17 Update 4), SIMATIC HMI KTP Mobile Panels (All v...","2022-10-11T11:15:10.94","2022-10-14T17:07:23.703",7.5,"CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:N\u002FI:N\u002FA:H",{"CVSSMetricV31":15,"CVSSMetricV30":26,"CVSSMetricV2":26,"CVSSMetricV40":26},[16],{"Source":17,"Type":18,"CVSSData":19,"ExploitabilityScore":27,"ImpactScore":28},"nvd@nist.gov","Primary",{"Version":20,"VectorString":13,"AttackVector":21,"AttackComplexity":22,"PrivilegesRequired":23,"UserInteraction":23,"Scope":24,"ConfidentialityImpact":23,"IntegrityImpact":23,"AvailabilityImpact":25,"BaseScore":12,"BaseSeverity":25,"ExploitCodeMaturity":26,"RemediationLevel":26,"ReportConfidence":26,"TemporalScore":26,"TemporalSeverity":26,"ConfidentialityRequirement":26,"IntegrityRequirement":26,"AvailabilityRequirement":25,"ModifiedAttackVector":26,"ModifiedAttackComplexity":26,"ModifiedPrivilegesRequired":26,"ModifiedUserInteraction":26,"ModifiedScope":26,"ModifiedConfidentialityImpact":26,"ModifiedIntegrityImpact":26,"ModifiedAvailabilityImpact":26,"EnvironmentalScore":26,"EnvironmentalSeverity":26},"3.1","NETWORK","LOW","NONE","UNCHANGED","HIGH",null,3.9,3.6,0.00917,[29,29,29,29,29,29,29],"High",[33,38,41,45,48,50,53,56,58,61,64,66,69,72,74,77,80,82,85,88,90,93,96,98,101,104,106,109,112,114],{"vendor":34,"product":35,"version":36,"criteria":37,"vulnerable":4},"siemens","simatic_hmi_comfort_panels_firmware","*","cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":35,"version":39,"criteria":40,"vulnerable":4},"17.0","cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":42,"version":43,"criteria":44,"vulnerable":4},"simatic_hmi_comfort_panels","-","cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",{"vendor":34,"product":46,"version":36,"criteria":47,"vulnerable":4},"simatic_hmi_ktp400_basic_firmware","cpe:2.3:o:siemens:simatic_hmi_ktp400_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":46,"version":39,"criteria":49,"vulnerable":4},"cpe:2.3:o:siemens:simatic_hmi_ktp400_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":51,"version":43,"criteria":52,"vulnerable":4},"simatic_hmi_ktp400_basic","cpe:2.3:h:siemens:simatic_hmi_ktp400_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":54,"version":36,"criteria":55,"vulnerable":4},"simatic_hmi_ktp700_basic_firmware","cpe:2.3:o:siemens:simatic_hmi_ktp700_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":54,"version":39,"criteria":57,"vulnerable":4},"cpe:2.3:o:siemens:simatic_hmi_ktp700_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":59,"version":43,"criteria":60,"vulnerable":4},"simatic_hmi_ktp700_basic","cpe:2.3:h:siemens:simatic_hmi_ktp700_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":62,"version":36,"criteria":63,"vulnerable":4},"simatic_hmi_ktp900_basic_firmware","cpe:2.3:o:siemens:simatic_hmi_ktp900_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":62,"version":39,"criteria":65,"vulnerable":4},"cpe:2.3:o:siemens:simatic_hmi_ktp900_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":67,"version":43,"criteria":68,"vulnerable":4},"simatic_hmi_ktp900_basic","cpe:2.3:h:siemens:simatic_hmi_ktp900_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":70,"version":36,"criteria":71,"vulnerable":4},"simatic_hmi_ktp1200_basic_firmware","cpe:2.3:o:siemens:simatic_hmi_ktp1200_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":70,"version":39,"criteria":73,"vulnerable":4},"cpe:2.3:o:siemens:simatic_hmi_ktp1200_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":75,"version":43,"criteria":76,"vulnerable":4},"simatic_hmi_ktp1200_basic","cpe:2.3:h:siemens:simatic_hmi_ktp1200_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":78,"version":36,"criteria":79,"vulnerable":4},"simatic_hmi_ktp_mobile_panels_firmware","cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":78,"version":39,"criteria":81,"vulnerable":4},"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":83,"version":43,"criteria":84,"vulnerable":4},"simatic_hmi_ktp_mobile_panels","cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",{"vendor":34,"product":86,"version":36,"criteria":87,"vulnerable":4},"siplus_hmi_ktp400_basic_firmware","cpe:2.3:o:siemens:siplus_hmi_ktp400_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":86,"version":39,"criteria":89,"vulnerable":4},"cpe:2.3:o:siemens:siplus_hmi_ktp400_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":91,"version":43,"criteria":92,"vulnerable":4},"siplus_hmi_ktp400_basic","cpe:2.3:h:siemens:siplus_hmi_ktp400_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":94,"version":36,"criteria":95,"vulnerable":4},"siplus_hmi_ktp700_basic_firmware","cpe:2.3:o:siemens:siplus_hmi_ktp700_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":94,"version":39,"criteria":97,"vulnerable":4},"cpe:2.3:o:siemens:siplus_hmi_ktp700_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":99,"version":43,"criteria":100,"vulnerable":4},"siplus_hmi_ktp700_basic","cpe:2.3:h:siemens:siplus_hmi_ktp700_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":102,"version":36,"criteria":103,"vulnerable":4},"siplus_hmi_ktp900_basic_firmware","cpe:2.3:o:siemens:siplus_hmi_ktp900_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":102,"version":39,"criteria":105,"vulnerable":4},"cpe:2.3:o:siemens:siplus_hmi_ktp900_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":107,"version":43,"criteria":108,"vulnerable":4},"siplus_hmi_ktp900_basic","cpe:2.3:h:siemens:siplus_hmi_ktp900_basic:-:*:*:*:*:*:*:*",{"vendor":34,"product":110,"version":36,"criteria":111,"vulnerable":4},"siplus_hmi_ktp1200_basic_firmware","cpe:2.3:o:siemens:siplus_hmi_ktp1200_basic_firmware:*:*:*:*:*:*:*:*",{"vendor":34,"product":110,"version":39,"criteria":113,"vulnerable":4},"cpe:2.3:o:siemens:siplus_hmi_ktp1200_basic_firmware:17.0:-:*:*:*:*:*:*",{"vendor":34,"product":115,"version":43,"criteria":116,"vulnerable":4},"siplus_hmi_ktp1200_basic","cpe:2.3:h:siemens:siplus_hmi_ktp1200_basic:-:*:*:*:*:*:*:*",30,[119],{"url":120,"source":121,"tags":122},"https:\u002F\u002Fcert-portal.siemens.com\u002Fproductcert\u002Fpdf\u002Fssa-384224.pdf","Siemens",[123],"Vendor Advisory",1,[126],{"id":127,"name":128,"description":129,"extendedDescription":130,"status":131,"abstraction":132,"structure":133},"CWE-20","Improper Input Validation","The product receives input or data, but it does\n        not validate or incorrectly validates that the input has the\n        properties that are required to process the data safely and\n        correctly.","Input validation is a frequently-used technique\n\t   for checking potentially dangerous inputs in order to\n\t   ensure that the inputs are safe for processing within the\n\t   code, or when communicating with other components.  When\n\t   software does not validate input properly, an attacker is\n\t   able to craft the input in a form that is not expected by\n\t   the rest of the application. This will lead to parts of the\n\t   system receiving unintended input, which may result in\n\t   altered control flow, arbitrary control of a resource, or\n\t   arbitrary code execution.\nInput validation is not the only technique for\n\t   processing input, however.  Other techniques attempt to\n\t   transform potentially-dangerous input into something safe, such\n\t   as filtering (CWE-790) - which attempts to remove dangerous\n\t   inputs - or encoding\u002Fescaping (CWE-116), which attempts to\n\t   ensure that the input is not misinterpreted when it is included\n\t   in output to another component. Other techniques exist as well\n\t   (see CWE-138 for more examples.)\nInput validation can be applied to:\nData can be simple or structured.  Structured data\n\t   can be composed of many nested layers, composed of\n\t   combinations of metadata and raw data, with other simple or\n\t   structured data.\nMany properties of raw data or metadata may need\n\t   to be validated upon entry into the code, such\n\t   as:\nImplied or derived properties of data must often\n\t   be calculated or inferred by the code itself.  Errors in\n\t   deriving properties may be considered a contributing factor\n\t   to improper input validation.\nNote that \"input validation\" has very different\n\t   meanings to different people, or within different\n\t   classification schemes.  Caution must be used when\n\t   referencing this CWE entry or mapping to it.  For example,\n\t   some weaknesses might involve inadvertently giving control\n\t   to an attacker over an input when they should not be able\n\t   to provide an input at all, but sometimes this is referred\n\t   to as input validation.\nFinally, it is important to emphasize that the\n\t   distinctions between input validation and output escaping\n\t   are often blurred, and developers must be careful to\n\t   understand the difference, including how input validation\n\t   is not always sufficient to prevent vulnerabilities,\n\t   especially when less stringent data types must be\n\t   supported, such as free-form text. Consider a SQL injection\n\t   scenario in which a person's last name is inserted into a\n\t   query. The name \"O'Reilly\" would likely pass the validation\n\t   step since it is a common last name in the English\n\t   language. However, this valid name cannot be directly\n\t   inserted into the database because it contains the \"'\"\n\t   apostrophe character, which would need to be escaped or\n\t   otherwise transformed. In this case, removing the\n\t   apostrophe might reduce the risk of SQL injection, but it\n\t   would produce incorrect behavior because the wrong name\n\t   would be recorded.","Stable","Class","Simple",false,[],{"title":137,"metaDescription":138,"keywords":139,"canonicalUrl":140,"structuredData":141},"What is CVE-2022-40227? Vulnerability Analysis | Security Advisory | Precursor Intelligence","Comprehensive analysis of CVE-2022-40227, a high severity cyber security vulnerability from 2022. A vulnerability has been identified in SIMATIC HMI Comfort ...","CVE-2022-40227, CVE-2022-40227 vulnerability, CVE-2022-40227 security, high severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2022, CVSS score, exploit, patch, remediation, siemens security, simatic_hmi_comfort_panels_firmware vulnerability, simatic_hmi_comfort_panels vulnerability, simatic_hmi_ktp400_basic_firmware vulnerability, simatic_hmi_ktp400_basic vulnerability, simatic_hmi_ktp700_basic_firmware vulnerability","\u002Fwhat-is\u002Fcve-2022-40227",{"@context":142,"@type":143,"headline":137,"description":138,"datePublished":10,"dateModified":11,"author":144,"publisher":148,"about":152,"mainEntityOfPage":156,"articleSection":159,"keywords":160},"https:\u002F\u002Fschema.org","TechArticle",{"@type":145,"name":146,"url":147},"Organization","Precursor Intelligence","https:\u002F\u002Fprecursorintelligence.com",{"@type":145,"name":146,"url":147,"logo":149},{"@type":150,"url":151},"ImageObject","https:\u002F\u002Fprecursorintelligence.com\u002Fimg\u002Flogos\u002Feplogo.png",{"@type":153,"name":6,"description":154,"additionalType":155},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":157,"@id":158},"WebPage","https:\u002F\u002Fprecursorintelligence.com\u002Fwhat-is\u002Fcve-2022-40227","Cybersecurity","CVE-2022-40227, CVE-2022-40227 vulnerability, CVE-2022-40227 security, high severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[162,185,209,233,257,281,302,326,350,374],{"Operator":163,"Negate":26,"Nodes":164},"AND",[165,181],{"Operator":166,"Negate":26,"CPEMatch":167},"OR",[168,170,172,175,178],{"Vulnerable":4,"Criteria":37,"MatchCriteriaID":169,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"8DCFD529-DCC6-42FE-8691-AE5B6695803D",{"Vulnerable":4,"Criteria":40,"MatchCriteriaID":171,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"4EBEE7D5-F809-4225-9A06-7206020EBFB7",{"Vulnerable":4,"Criteria":173,"MatchCriteriaID":174,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:17.0:update1:*:*:*:*:*:*","B09B136A-D79C-479F-B8C3-8205D9C07096",{"Vulnerable":4,"Criteria":176,"MatchCriteriaID":177,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:17.0:update2:*:*:*:*:*:*","746EF905-2BE7-4D2D-A835-BD45A7EC0E20",{"Vulnerable":4,"Criteria":179,"MatchCriteriaID":180,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:17.0:update3:*:*:*:*:*:*","BACB3952-99E2-4435-9ED8-062121F64B74",{"Operator":166,"Negate":26,"CPEMatch":182},[183],{"Vulnerable":26,"Criteria":44,"MatchCriteriaID":184,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"3BCFE761-35C9-43EF-85BC-E8083B9F75CB",{"Operator":163,"Negate":26,"Nodes":186},[187,205],{"Operator":166,"Negate":26,"CPEMatch":188},[189,191,193,196,199,202],{"Vulnerable":4,"Criteria":47,"MatchCriteriaID":190,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"EB67AB83-24D3-44C7-88EB-9F86C1377FE6",{"Vulnerable":4,"Criteria":49,"MatchCriteriaID":192,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"9C1B107D-7299-4B35-8B8A-2C7604D7E053",{"Vulnerable":4,"Criteria":194,"MatchCriteriaID":195,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp400_basic_firmware:17.0:udpate1:*:*:*:*:*:*","4CC31D37-01CC-47BF-B914-C01D67E5F7CF",{"Vulnerable":4,"Criteria":197,"MatchCriteriaID":198,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp400_basic_firmware:17.0:update2:*:*:*:*:*:*","EB517965-7DEA-4F36-9F8C-CD2ACA70011E",{"Vulnerable":4,"Criteria":200,"MatchCriteriaID":201,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp400_basic_firmware:17.0:update3:*:*:*:*:*:*","30D445ED-DCC8-48CC-9964-99594941E0C2",{"Vulnerable":4,"Criteria":203,"MatchCriteriaID":204,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp400_basic_firmware:17.0:update4:*:*:*:*:*:*","8F89742F-A83A-47D4-9B7B-FC938E122374",{"Operator":166,"Negate":26,"CPEMatch":206},[207],{"Vulnerable":26,"Criteria":52,"MatchCriteriaID":208,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"0222A331-0D6B-4CF0-AAC8-8874A8C2920D",{"Operator":163,"Negate":26,"Nodes":210},[211,229],{"Operator":166,"Negate":26,"CPEMatch":212},[213,215,217,220,223,226],{"Vulnerable":4,"Criteria":55,"MatchCriteriaID":214,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"8AC9BB91-C4E1-4EE3-8FB6-011D81E335B2",{"Vulnerable":4,"Criteria":57,"MatchCriteriaID":216,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"EBE0FA3D-E20D-4428-9882-04008F77D7DF",{"Vulnerable":4,"Criteria":218,"MatchCriteriaID":219,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp700_basic_firmware:17.0:udpate1:*:*:*:*:*:*","893C0FF7-56D7-42C5-8175-E9A220D9FD8B",{"Vulnerable":4,"Criteria":221,"MatchCriteriaID":222,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp700_basic_firmware:17.0:update2:*:*:*:*:*:*","917B4B04-4AED-45C9-AB84-6C2033666284",{"Vulnerable":4,"Criteria":224,"MatchCriteriaID":225,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp700_basic_firmware:17.0:update3:*:*:*:*:*:*","F5DD16C0-2E48-44F5-9702-80370285A6A7",{"Vulnerable":4,"Criteria":227,"MatchCriteriaID":228,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp700_basic_firmware:17.0:update4:*:*:*:*:*:*","E521B7A5-C8BD-4CBD-8D07-7173523D9947",{"Operator":166,"Negate":26,"CPEMatch":230},[231],{"Vulnerable":26,"Criteria":60,"MatchCriteriaID":232,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"D8615AE0-0560-4026-89E5-9122F7846318",{"Operator":163,"Negate":26,"Nodes":234},[235,253],{"Operator":166,"Negate":26,"CPEMatch":236},[237,239,241,244,247,250],{"Vulnerable":4,"Criteria":63,"MatchCriteriaID":238,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"76F77DAF-1863-4DA7-8900-56A2C3377F56",{"Vulnerable":4,"Criteria":65,"MatchCriteriaID":240,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"3F4D22C3-1A81-4CC0-94EA-D4B5AEF7103C",{"Vulnerable":4,"Criteria":242,"MatchCriteriaID":243,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp900_basic_firmware:17.0:udpate1:*:*:*:*:*:*","66CF9CE6-C351-4F55-9CEC-EF28237A6765",{"Vulnerable":4,"Criteria":245,"MatchCriteriaID":246,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp900_basic_firmware:17.0:update2:*:*:*:*:*:*","1A113518-2D32-4C1F-ADEA-F02A24509454",{"Vulnerable":4,"Criteria":248,"MatchCriteriaID":249,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp900_basic_firmware:17.0:update3:*:*:*:*:*:*","8264F3AE-8DFF-4462-8073-BDCD45A874D4",{"Vulnerable":4,"Criteria":251,"MatchCriteriaID":252,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp900_basic_firmware:17.0:update4:*:*:*:*:*:*","DA5DB18E-258F-4E50-97D6-B4067F747F9C",{"Operator":166,"Negate":26,"CPEMatch":254},[255],{"Vulnerable":26,"Criteria":68,"MatchCriteriaID":256,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"9D2CB1B6-8864-486F-B6F8-9008367C5520",{"Operator":163,"Negate":26,"Nodes":258},[259,277],{"Operator":166,"Negate":26,"CPEMatch":260},[261,263,265,268,271,274],{"Vulnerable":4,"Criteria":71,"MatchCriteriaID":262,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"50D8577F-6CE5-4407-A875-06321EEEA38E",{"Vulnerable":4,"Criteria":73,"MatchCriteriaID":264,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"9BAD5042-0834-44DB-984D-BBC15F61C336",{"Vulnerable":4,"Criteria":266,"MatchCriteriaID":267,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp1200_basic_firmware:17.0:udpate1:*:*:*:*:*:*","D9DA5CB7-6566-4941-980A-AEE3FB303823",{"Vulnerable":4,"Criteria":269,"MatchCriteriaID":270,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp1200_basic_firmware:17.0:update2:*:*:*:*:*:*","6C724EA7-F8D2-41A3-83D1-584980D49879",{"Vulnerable":4,"Criteria":272,"MatchCriteriaID":273,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp1200_basic_firmware:17.0:update3:*:*:*:*:*:*","6DA2E685-01A0-4CFE-B0C9-457F5EF7319F",{"Vulnerable":4,"Criteria":275,"MatchCriteriaID":276,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp1200_basic_firmware:17.0:update4:*:*:*:*:*:*","73087669-4164-4A95-AB5B-652032BCD204",{"Operator":166,"Negate":26,"CPEMatch":278},[279],{"Vulnerable":26,"Criteria":76,"MatchCriteriaID":280,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"CF65C523-5AFA-46C4-BB97-5E540A4FAF33",{"Operator":163,"Negate":26,"Nodes":282},[283,298],{"Operator":166,"Negate":26,"CPEMatch":284},[285,287,289,292,295],{"Vulnerable":4,"Criteria":79,"MatchCriteriaID":286,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"B580B36D-225C-4826-A9F7-18B98B5F6ADC",{"Vulnerable":4,"Criteria":81,"MatchCriteriaID":288,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"072043EB-B855-4F1A-A326-F135C557FC1C",{"Vulnerable":4,"Criteria":290,"MatchCriteriaID":291,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:17.0:udpate1:*:*:*:*:*:*","EBC6C232-8DA0-46EA-9F45-6C71E43622D5",{"Vulnerable":4,"Criteria":293,"MatchCriteriaID":294,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:17.0:update2:*:*:*:*:*:*","8981B34C-287F-4121-9CF7-5F08D79D50FA",{"Vulnerable":4,"Criteria":296,"MatchCriteriaID":297,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:17.0:update3:*:*:*:*:*:*","34D094D0-A74A-4924-A969-A60E4BFC63B7",{"Operator":166,"Negate":26,"CPEMatch":299},[300],{"Vulnerable":26,"Criteria":84,"MatchCriteriaID":301,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"B1CEB200-E38F-4629-9279-5AF065396678",{"Operator":163,"Negate":26,"Nodes":303},[304,322],{"Operator":166,"Negate":26,"CPEMatch":305},[306,308,310,313,316,319],{"Vulnerable":4,"Criteria":87,"MatchCriteriaID":307,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"3CDE46F2-DDE2-448F-9F50-324D3D5BAAAF",{"Vulnerable":4,"Criteria":89,"MatchCriteriaID":309,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"3933A5FE-62D7-407D-A381-0132ECC87B95",{"Vulnerable":4,"Criteria":311,"MatchCriteriaID":312,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp400_basic_firmware:17.0:udpate1:*:*:*:*:*:*","B8D306FA-B376-431E-87AE-CECBB36D579A",{"Vulnerable":4,"Criteria":314,"MatchCriteriaID":315,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp400_basic_firmware:17.0:update2:*:*:*:*:*:*","9D45398C-11BE-4074-B48D-2B59A1861706",{"Vulnerable":4,"Criteria":317,"MatchCriteriaID":318,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp400_basic_firmware:17.0:update3:*:*:*:*:*:*","78B8C304-65CC-4AF4-8CD9-1ADC4F75FD79",{"Vulnerable":4,"Criteria":320,"MatchCriteriaID":321,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp400_basic_firmware:17.0:update4:*:*:*:*:*:*","93D82946-53FC-456F-AC56-7F29EE7B8CED",{"Operator":166,"Negate":26,"CPEMatch":323},[324],{"Vulnerable":26,"Criteria":92,"MatchCriteriaID":325,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"2AC3E1B0-CC2B-4C34-AB6F-C61D2DF8DCA2",{"Operator":163,"Negate":26,"Nodes":327},[328,346],{"Operator":166,"Negate":26,"CPEMatch":329},[330,332,334,337,340,343],{"Vulnerable":4,"Criteria":95,"MatchCriteriaID":331,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"3D7E344E-50C0-46CB-BB23-DBD9C6D587EC",{"Vulnerable":4,"Criteria":97,"MatchCriteriaID":333,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"0A97BEBC-ED88-4FA7-B3E2-00398B454038",{"Vulnerable":4,"Criteria":335,"MatchCriteriaID":336,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp700_basic_firmware:17.0:udpate1:*:*:*:*:*:*","E15BF5CD-F348-4AD5-A86A-4DE4436ECB5D",{"Vulnerable":4,"Criteria":338,"MatchCriteriaID":339,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp700_basic_firmware:17.0:update2:*:*:*:*:*:*","70BDFDFF-3B0E-4180-B525-C36D47D49655",{"Vulnerable":4,"Criteria":341,"MatchCriteriaID":342,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp700_basic_firmware:17.0:update3:*:*:*:*:*:*","970D3ED3-27A1-4960-B3B6-21733D9E4943",{"Vulnerable":4,"Criteria":344,"MatchCriteriaID":345,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp700_basic_firmware:17.0:update4:*:*:*:*:*:*","E3BD885C-F063-41C6-837B-50281269611E",{"Operator":166,"Negate":26,"CPEMatch":347},[348],{"Vulnerable":26,"Criteria":100,"MatchCriteriaID":349,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"01AADB5B-4072-447D-A9BF-A0108334D727",{"Operator":163,"Negate":26,"Nodes":351},[352,370],{"Operator":166,"Negate":26,"CPEMatch":353},[354,356,358,361,364,367],{"Vulnerable":4,"Criteria":103,"MatchCriteriaID":355,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"0426D469-72EE-4D66-987E-C21BDB9867CB",{"Vulnerable":4,"Criteria":105,"MatchCriteriaID":357,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"431D187E-A8F3-4586-B7C8-72D98976A59B",{"Vulnerable":4,"Criteria":359,"MatchCriteriaID":360,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp900_basic_firmware:17.0:udpate1:*:*:*:*:*:*","D652CF29-8521-45B3-AA50-55F3D4D83140",{"Vulnerable":4,"Criteria":362,"MatchCriteriaID":363,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp900_basic_firmware:17.0:update2:*:*:*:*:*:*","DADE0CDD-474E-48C5-9A17-3B9621B34218",{"Vulnerable":4,"Criteria":365,"MatchCriteriaID":366,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp900_basic_firmware:17.0:update3:*:*:*:*:*:*","1BDE0B2E-B8D4-4FD1-85B0-DAD4B5AAC160",{"Vulnerable":4,"Criteria":368,"MatchCriteriaID":369,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp900_basic_firmware:17.0:update4:*:*:*:*:*:*","02CE0AF1-7EC1-4CEF-BD42-7C4AD2684A71",{"Operator":166,"Negate":26,"CPEMatch":371},[372],{"Vulnerable":26,"Criteria":108,"MatchCriteriaID":373,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"0C79F9E9-D9B6-4D6B-9B6F-006E3268EEAC",{"Operator":163,"Negate":26,"Nodes":375},[376,394],{"Operator":166,"Negate":26,"CPEMatch":377},[378,380,382,385,388,391],{"Vulnerable":4,"Criteria":111,"MatchCriteriaID":379,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":39,"VersionEndIncluding":26},"11713C91-C989-417A-85F3-6744E9F420A4",{"Vulnerable":4,"Criteria":113,"MatchCriteriaID":381,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"031AEC4F-FCE6-4F79-B372-4D07485E20A7",{"Vulnerable":4,"Criteria":383,"MatchCriteriaID":384,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp1200_basic_firmware:17.0:udpate1:*:*:*:*:*:*","881F137C-1F01-4225-9257-08ED9F53583C",{"Vulnerable":4,"Criteria":386,"MatchCriteriaID":387,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp1200_basic_firmware:17.0:update2:*:*:*:*:*:*","4B9DB1DC-EC61-4B84-8624-863B4E4954AF",{"Vulnerable":4,"Criteria":389,"MatchCriteriaID":390,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp1200_basic_firmware:17.0:update3:*:*:*:*:*:*","2019CF4C-4555-4357-8B8B-63895206BEE6",{"Vulnerable":4,"Criteria":392,"MatchCriteriaID":393,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"cpe:2.3:o:siemens:siplus_hmi_ktp1200_basic_firmware:17.0:update4:*:*:*:*:*:*","B92136E9-C281-43BB-BF65-EC8729C31BB0",{"Operator":166,"Negate":26,"CPEMatch":395},[396],{"Vulnerable":26,"Criteria":116,"MatchCriteriaID":397,"VersionStartExcluding":26,"VersionStartIncluding":26,"VersionEndExcluding":26,"VersionEndIncluding":26},"F3F61D1C-1127-4F37-BA30-3F36830FDF20",[],[],{"lastModified":11,"cacheTime":401,"version":402},1792373679554,"2.0",{"score":404,"band":405,"action":406,"scoredAt":407},46,"Medium","Plan remediation","2026-10-16T06:55:55.386731+00:00"]