[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f1n3WyigE_qF3r9QUj0exJDWs34G0Kr0sEK4NlVOzxZc":3,"g5a-risk:CVE-2025-27539":105},{"success":4,"data":5,"meta":102},true,{"cveId":6,"title":7,"description":8,"shortDescription":9,"publishedDate":10,"lastModified":11,"cvssScore":12,"cvssVector":13,"cvssMetrics":14,"epssScore":32,"epssPercentile":27,"epssTimeSeries":33,"severity":34,"affectedProducts":35,"affectedProductsCount":41,"references":42,"referencesCount":41,"weaknesses":48,"weaknessesCount":41,"isActivelyExploited":57,"cisaInfo":27,"otxData":27,"relatedBlogPosts":58,"seoMetadata":59,"configurations":84,"relatedVendorCves":93,"notableEvents":94},"CVE-2025-27539","What is CVE-2025-27539?","A vulnerability has been identified in TeleControl Server Basic (All versions \u003C V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.  (ZDI-CAN-25914)","A vulnerability has been identified in TeleControl Server Basic (All versions \u003C V3.1.2.2). The affected application is vulnerable to SQL injection through th...","2025-04-16T18:16:04.477","2025-08-19T14:49:14.68",9.8,"CVSS:3.1\u002FAV:N\u002FAC:L\u002FPR:N\u002FUI:N\u002FS:U\u002FC:H\u002FI:H\u002FA:H",{"CVSSMetricV31":15,"CVSSMetricV30":30,"CVSSMetricV2":31,"CVSSMetricV40":27},[16],{"Source":17,"Type":18,"CVSSData":19,"ExploitabilityScore":28,"ImpactScore":29},"productcert@siemens.com","Primary",{"Version":20,"VectorString":13,"AttackVector":21,"AttackComplexity":22,"PrivilegesRequired":23,"UserInteraction":23,"Scope":24,"ConfidentialityImpact":25,"IntegrityImpact":25,"AvailabilityImpact":25,"BaseScore":12,"BaseSeverity":26,"ExploitCodeMaturity":27,"RemediationLevel":27,"ReportConfidence":27,"TemporalScore":27,"TemporalSeverity":27,"ConfidentialityRequirement":27,"IntegrityRequirement":27,"AvailabilityRequirement":27,"ModifiedAttackVector":27,"ModifiedAttackComplexity":27,"ModifiedPrivilegesRequired":27,"ModifiedUserInteraction":27,"ModifiedScope":27,"ModifiedConfidentialityImpact":27,"ModifiedIntegrityImpact":27,"ModifiedAvailabilityImpact":27,"EnvironmentalScore":27,"EnvironmentalSeverity":27},"3.1","NETWORK","LOW","NONE","UNCHANGED","HIGH","CRITICAL",null,3.9,5.9,[],[],0.01015,[32,32,32,32,32,32,32],"Critical",[36],{"vendor":37,"product":38,"version":39,"criteria":40,"vulnerable":4},"siemens","telecontrol_server_basic","*","cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",1,[43],{"url":44,"source":45,"tags":46},"https:\u002F\u002Fcert-portal.siemens.com\u002Fproductcert\u002Fhtml\u002Fssa-443402.html","Siemens",[47],"Vendor Advisory",[49],{"id":50,"name":51,"description":52,"extendedDescription":53,"status":54,"abstraction":55,"structure":56},"CWE-89","Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')","The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data.","","Stable","Base","Simple",false,[],{"title":60,"metaDescription":61,"keywords":62,"canonicalUrl":63,"structuredData":64},"What is CVE-2025-27539? Vulnerability Analysis | Security Advisory | Precursor Intelligence","Comprehensive analysis of CVE-2025-27539, a critical severity cyber security vulnerability from 2025. A vulnerability has been identified in TeleControl Serv...","CVE-2025-27539, CVE-2025-27539 vulnerability, CVE-2025-27539 security, critical severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research, vulnerability assessment, cyber threats, 2025, CVSS score, exploit, patch, remediation, siemens security, telecontrol_server_basic vulnerability","\u002Fwhat-is\u002Fcve-2025-27539",{"@context":65,"@type":66,"headline":60,"description":61,"datePublished":10,"dateModified":11,"author":67,"publisher":71,"about":75,"mainEntityOfPage":79,"articleSection":82,"keywords":83},"https:\u002F\u002Fschema.org","TechArticle",{"@type":68,"name":69,"url":70},"Organization","Precursor Intelligence","https:\u002F\u002Fprecursorintelligence.com",{"@type":68,"name":69,"url":70,"logo":72},{"@type":73,"url":74},"ImageObject","https:\u002F\u002Fprecursorintelligence.com\u002Fimg\u002Flogos\u002Feplogo.png",{"@type":76,"name":6,"description":77,"additionalType":78},"Thing","Cybersecurity Vulnerability","https:\u002F\u002Fschema.org\u002FSoftwareBug",{"@type":80,"@id":81},"WebPage","https:\u002F\u002Fprecursorintelligence.com\u002Fwhat-is\u002Fcve-2025-27539","Cybersecurity","CVE-2025-27539, CVE-2025-27539 vulnerability, CVE-2025-27539 security, critical severity vulnerability, cybersecurity, vulnerability analysis, security advisory, CVE database, threat intelligence, security research",[85],{"Operator":27,"Negate":27,"Nodes":86},[87],{"Operator":88,"Negate":57,"CPEMatch":89},"OR",[90],{"Vulnerable":4,"Criteria":40,"MatchCriteriaID":91,"VersionStartExcluding":27,"VersionStartIncluding":27,"VersionEndExcluding":92,"VersionEndIncluding":27},"5A439C0E-7853-489C-93A5-40596265F6D0","3.1.2.2",[],[95],{"id":96,"eventType":97,"eventTime":98,"details":99,"label":100,"color":101},"b56cfb12-9a78-429b-9ea9-47e77cbe18f2","NEW_NVD","2025-04-17T02:15:36.740056+00:00","New CVE added to NVD","Published to NVD","blue",{"lastModified":11,"cacheTime":103,"version":104},1792366594140,"2.0",{"score":106,"band":107,"action":108,"scoredAt":109},54,"Medium","Plan remediation","2026-10-16T07:06:52.928172+00:00"]