Bmxnor0200 Firmware vulnerabilitiesRanked by how likely they are to be used.
Bmxnor0200 Firmware is made by Schneider-Electric. We track 6 published vulnerabilities in it, across 0 versions. None of them is on the list of flaws known to be exploited today. If you run Bmxnor0200 Firmware, keep it on a version the vendor still supports.
We keep watching the known-exploited list.
Which Bmxnor0200 Firmware vulnerabilities are being exploited?
This is the list that matters most: flaws criminals are using now.
None of Bmxnor0200 Firmware's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.
Which Bmxnor0200 Firmware flaws are most likely to be used?
Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.
- 3.7%CVE-2018-7241Critical
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
- 2.1%CVE-2018-7761Critical
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
- 1.9%CVE-2018-7242Critical
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
- 1.5%CVE-2018-7760Critical
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.
- 1.3%CVE-2018-7759High
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.
- 1.3%CVE-2018-7762High
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
Running Bmxnor0200 Firmware? We'll keep checking.
Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.
- Tell us what you runPick your software from a list, or let us work it out from your website.
- We match it to every flawOver 400,000 published flaws, checked against your list.
- Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
- Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.
Free plan, no card needed. Nothing to install.
1 new flaw affects software Acme tracks
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
- Matched to
- Bmxnor0200 Firmware on Acme's software list
- What to do
- Plan in the vendor’s update
Sent to the alert recipients Acme chose. Also in the app and to Acme's webhook.
We track 6 published vulnerabilities listed under the name Bmxnor0200 Firmware, across 0 versions.
None of Bmxnor0200 Firmware's vulnerabilities is on the list of flaws known to be exploited today.
Create a Precursor Intelligence account and track Bmxnor0200 Firmware. We match it against every published flaw, give each one a risk score from 0 to 100 and keep watching, so you hear about new ones as soon as we know, by email, in the app or by webhook.