Citectscada vulnerabilitiesRanked by how likely they are to be used.

Product4 versions
The short answer

Citectscada is made by Schneider-Electric. We track 6 published vulnerabilities listed under that exact name, across 4 versions. None of them is on the list of flaws known to be exploited today. Schneider-Electric lists newer releases under their own names, such as Citectscada Reports, so check those pages too.

See the riskiest flaws

We keep watching the known-exploited list.

Other names

Is Citectscada listed under other names? Yes.

Schneider-Electric also lists Citectscada under more specific names, such as Citectscada Reports. Flaws listed only under those names are counted on their own pages, not here. If you run one of these, open its page for its own exploited flaws.

Known exploited

Which Citectscada vulnerabilities are being exploited?

This is the list that matters most: flaws criminals are using now.

None of Citectscada's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.

Exploit likelihood

Which Citectscada flaws are most likely to be used?

Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.

50% or more10% to 49%Under 10%
  1. 11%

    Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long...

    CVSS10.0Published19 Apr 2013
  2. 0.7%

    Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a...

    CVSS6.9Published9 Aug 2013
  3. 0.5%

    Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long...

    CVSS4.6Published15 Sep 2012
  4. 0.5%

    A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo...

    CVSS7.3Published25 Mar 2019
  5. 0.4%

    In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.

    CVSS7.8Published31 May 2019
Precursor Intelligence

Running Citectscada? We'll keep checking.

Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.

  1. Tell us what you runPick your software from a list, or let us work it out from your website.
  2. We match it to every flawOver 400,000 published flaws, checked against your list.
  3. Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
  4. Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.

Free plan, no card needed. Nothing to install.

FAQ

Common questions, answered plainly.

Something else? Talk to the team →

We track 6 published vulnerabilities listed under the name Citectscada, across 4 versions.

None of Citectscada's vulnerabilities is on the list of flaws known to be exploited today.

Schneider-Electric also lists Citectscada under more specific names, such as Citectscada Reports. Flaws listed only under those names are counted on their own pages, not here. Open the release you run to see its own list.