Interactive Graphical SCADA System Data Collector vulnerabilitiesRanked by how likely they are to be used.
Interactive Graphical SCADA System Data Collector is made by Schneider-Electric. We track 6 published vulnerabilities in it, across 0 versions. None of them is on the list of flaws known to be exploited today. If you run Interactive Graphical SCADA System Data Collector, keep it on a version the vendor still supports.
We keep watching the known-exploited list.
Which Interactive Graphical SCADA System Data Collector vulnerabilities are being exploited?
This is the list that matters most: flaws criminals are using now.
None of Interactive Graphical SCADA System Data Collector's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.
Which Interactive Graphical SCADA System Data Collector flaws are most likely to be used?
Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.
- 21%CVE-2021-22823Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages.
- 20%CVE-2021-22802Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the...
- 14%CVE-2021-22824High
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network.
- 1.9%CVE-2021-22803Critical
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of...
- 1.3%CVE-2021-22804High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation...
- 0.9%CVE-2021-22805Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages.
Running Interactive Graphical SCADA System Data Collector? We'll keep checking.
Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.
- Tell us what you runPick your software from a list, or let us work it out from your website.
- We match it to every flawOver 400,000 published flaws, checked against your list.
- Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
- Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.
Free plan, no card needed. Nothing to install.
1 new flaw affects software Acme tracks
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
- Matched to
- Interactive Graphical SCADA System Data Collector on Acme's software list
- What to do
- Plan in the vendor’s update
Sent to the alert recipients Acme chose. Also in the app and to Acme's webhook.
We track 6 published vulnerabilities listed under the name Interactive Graphical SCADA System Data Collector, across 0 versions.
None of Interactive Graphical SCADA System Data Collector's vulnerabilities is on the list of flaws known to be exploited today.
Create a Precursor Intelligence account and track Interactive Graphical SCADA System Data Collector. We match it against every published flaw, give each one a risk score from 0 to 100 and keep watching, so you hear about new ones as soon as we know, by email, in the app or by webhook.