Interactive Graphical SCADA System Data Server vulnerabilitiesRanked by how likely they are to be used.

Product0 versions
The short answer

Interactive Graphical SCADA System Data Server is made by Schneider-Electric. We track 8 published vulnerabilities in it, across 0 versions. None of them is on the list of flaws known to be exploited today. If you run Interactive Graphical SCADA System Data Server, keep it on a version the vendor still supports.

See the riskiest flaws

We keep watching the known-exploited list.

Known exploited

Which Interactive Graphical SCADA System Data Server vulnerabilities are being exploited?

This is the list that matters most: flaws criminals are using now.

None of Interactive Graphical SCADA System Data Server's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.

Exploit likelihood

Which Interactive Graphical SCADA System Data Server flaws are most likely to be used?

Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.

50% or more10% to 49%Under 10%
  1. 45%

    A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message.

    CVSS9.8Published9 Feb 2022
  2. 19%

    A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message.

    CVSS7.5Published9 Feb 2022
  3. 18%

    A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message.

    CVSS7.5Published9 Feb 2022
  4. 3.5%

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at beginning of file or create a new file in the context of...

    CVSS9.8Published9 Feb 2022
  5. 3.5%

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end of file or create a new file in the context of the Data...

    CVSS9.8Published9 Feb 2022
  6. 2.2%

    A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially...

    CVSS9.8Published9 Feb 2022
  7. 1.3%

    A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message.

    CVSS7.5Published9 Feb 2022
  8. 1.2%

    A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message.

    CVSS7.5Published9 Feb 2022
Precursor Intelligence

Running Interactive Graphical SCADA System Data Server? We'll keep checking.

Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.

  1. Tell us what you runPick your software from a list, or let us work it out from your website.
  2. We match it to every flawOver 400,000 published flaws, checked against your list.
  3. Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
  4. Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.

Free plan, no card needed. Nothing to install.

FAQ

Common questions, answered plainly.

Something else? Talk to the team →

We track 8 published vulnerabilities listed under the name Interactive Graphical SCADA System Data Server, across 0 versions.

None of Interactive Graphical SCADA System Data Server's vulnerabilities is on the list of flaws known to be exploited today.

Create a Precursor Intelligence account and track Interactive Graphical SCADA System Data Server. We match it against every published flaw, give each one a risk score from 0 to 100 and keep watching, so you hear about new ones as soon as we know, by email, in the app or by webhook.