Modicon M340 Bmxp341000 vulnerabilitiesRanked by how likely they are to be used.
Modicon M340 Bmxp341000 is made by Schneider-Electric. We track 33 published vulnerabilities listed under that exact name, across 0 versions. None of them is on the list of flaws known to be exploited today. Schneider-Electric lists newer releases under their own names, such as Modicon M340 Bmxp341000 Firmware, so check those pages too.
We keep watching the known-exploited list.
Is Modicon M340 Bmxp341000 listed under other names? Yes.
Schneider-Electric also lists Modicon M340 Bmxp341000 under more specific names, such as Modicon M340 Bmxp341000 Firmware. Flaws listed only under those names are counted on their own pages, not here. If you run one of these, open its page for its own exploited flaws.
Which Modicon M340 Bmxp341000 vulnerabilities are being exploited?
This is the list that matters most: flaws criminals are using now.
None of Modicon M340 Bmxp341000's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.
Which Modicon M340 Bmxp341000 flaws are most likely to be used?
Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.
- 3.7%CVE-2018-7241Critical
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
- 2.3%CVE-2020-7533Critical
CWE-287: Improper Authentication vulnerability exists which could cause the execution of commands on the webserver without authentication when sending specially crafted HTTP requests.
- 2.3%CVE-2020-7540Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security...
- 2.1%CVE-2013-2763Medium
The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors.
- 2.1%CVE-2018-7761Critical
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
- 1.9%CVE-2018-7242Critical
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
- 1.5%CVE-2020-7535High
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium...
- 1.5%CVE-2018-7760Critical
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.
- 1.5%CVE-2022-45789Critical
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session.
Running Modicon M340 Bmxp341000? We'll keep checking.
Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.
- Tell us what you runPick your software from a list, or let us work it out from your website.
- We match it to every flawOver 400,000 published flaws, checked against your list.
- Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
- Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.
Free plan, no card needed. Nothing to install.
1 new flaw affects software Acme tracks
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
- Matched to
- Modicon M340 Bmxp341000 on Acme's software list
- What to do
- Plan in the vendor’s update
Sent to the alert recipients Acme chose. Also in the app and to Acme's webhook.
We track 33 published vulnerabilities listed under the name Modicon M340 Bmxp341000, across 0 versions.
None of Modicon M340 Bmxp341000's vulnerabilities is on the list of flaws known to be exploited today.
Schneider-Electric also lists Modicon M340 Bmxp341000 under more specific names, such as Modicon M340 Bmxp341000 Firmware. Flaws listed only under those names are counted on their own pages, not here. Open the release you run to see its own list.
Create a Precursor Intelligence account and track Modicon M340 Bmxp341000. We match it against every published flaw, give each one a risk score from 0 to 100 and keep watching, so you hear about new ones as soon as we know, by email, in the app or by webhook.