Modicon M580 Bmeh582040c vulnerabilitiesRanked by how likely they are to be used.
Modicon M580 Bmeh582040c is made by Schneider-Electric. We track 11 published vulnerabilities listed under that exact name, across 0 versions. None of them is on the list of flaws known to be exploited today. Schneider-Electric lists newer releases under their own names, such as Modicon M580 Bmeh582040c Firmware, so check those pages too.
We keep watching the known-exploited list.
Is Modicon M580 Bmeh582040c listed under other names? Yes.
Schneider-Electric also lists Modicon M580 Bmeh582040c under more specific names, such as Modicon M580 Bmeh582040c Firmware. Flaws listed only under those names are counted on their own pages, not here. If you run one of these, open its page for its own exploited flaws.
Which Modicon M580 Bmeh582040c vulnerabilities are being exploited?
This is the list that matters most: flaws criminals are using now.
None of Modicon M580 Bmeh582040c's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.
Which Modicon M580 Bmeh582040c flaws are most likely to be used?
Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.
- 1.5%CVE-2022-45789Critical
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session.
- 1.2%CVE-2022-45788Critical
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file...
- 1.1%CVE-2021-22779Critical
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process...
- 0.9%CVE-2021-22792High
A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists...
- 0.8%CVE-2021-22789Medium
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application...
- 0.8%CVE-2021-22790Medium
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in...
- 0.8%CVE-2021-22791Medium
A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in...
- 0.8%CVE-2022-37300Critical
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus.
- 0.8%CVE-2022-37301High
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol.
- 0.6%CVE-2021-22786High
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol.
Running Modicon M580 Bmeh582040c? We'll keep checking.
Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.
- Tell us what you runPick your software from a list, or let us work it out from your website.
- We match it to every flawOver 400,000 published flaws, checked against your list.
- Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
- Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.
Free plan, no card needed. Nothing to install.
1 new flaw affects software Acme tracks
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
- Matched to
- Modicon M580 Bmeh582040c on Acme's software list
- What to do
- Plan in the vendor’s update
Sent to the alert recipients Acme chose. Also in the app and to Acme's webhook.
We track 11 published vulnerabilities listed under the name Modicon M580 Bmeh582040c, across 0 versions.
None of Modicon M580 Bmeh582040c's vulnerabilities is on the list of flaws known to be exploited today.
Schneider-Electric also lists Modicon M580 Bmeh582040c under more specific names, such as Modicon M580 Bmeh582040c Firmware. Flaws listed only under those names are counted on their own pages, not here. Open the release you run to see its own list.
Create a Precursor Intelligence account and track Modicon M580 Bmeh582040c. We match it against every published flaw, give each one a risk score from 0 to 100 and keep watching, so you hear about new ones as soon as we know, by email, in the app or by webhook.