Scalance S615 vulnerabilitiesRanked by how likely they are to be used.

Product0 versions
The short answer

Scalance S615 is made by Siemens. We track 24 published vulnerabilities listed under that exact name, across 0 versions. None of them is on the list of flaws known to be exploited today. Siemens lists newer releases under their own names, such as Scalance S615 Firmware, so check those pages too.

See the riskiest flaws

We keep watching the known-exploited list.

Other names

Is Scalance S615 listed under other names? Yes.

Siemens also lists Scalance S615 under more specific names, such as Scalance S615 Firmware and Scalance S615 Eec Firmware. Flaws listed only under those names are counted on their own pages, not here. If you run one of these, open its page for its own exploited flaws.

Known exploited

Which Scalance S615 vulnerabilities are being exploited?

This is the list that matters most: flaws criminals are using now.

None of Scalance S615's published vulnerabilities is on the list of flaws known to be exploited today. We keep watching that list.

Exploit likelihood

Which Scalance S615 flaws are most likely to be used?

Ranked by the latest exploit-likelihood forecast: the chance each flaw is used in an attack in the next 30 days. A high severity score on its own doesn't tell you that. Flaws shared by many other makers' products are left out.

50% or more10% to 49%Under 10%
  1. 85%

    Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.

    CVSS9.8Published4 Oct 2017
  2. 64%

    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client.

    CVSS5.9Published25 Mar 2021
  3. 32%

    The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly.

    CVSS7.5Published6 Sep 2018
  4. 6.3%

    libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert'...

    CVSS3.7Published5 Aug 2021
  5. 1.9%

    The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to...

    CVSS4.0Published29 Sep 2016
  6. 1.9%

    Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition.

    CVSS7.5Published13 Jul 2021
  7. 1.8%

    Affected devices do not properly sanitize an input field.

    CVSS9.1Published10 Aug 2022
  8. 1.7%

    Affected devices do not properly handle the renegotiation of SSL/TLS parameters.

    CVSS7.5Published10 Aug 2022
  9. 1.5%

    Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface.

    CVSS7.5Published11 Feb 2020
  10. 1.3%

    A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3).

    CVSS7.5Published15 Mar 2021
Precursor Intelligence

Running Scalance S615? We'll keep checking.

Looking flaws up one at a time doesn't scale. Tell us what you run once, and we tell you which flaws matter to you, in what order, and keep watching for new ones.

  1. Tell us what you runPick your software from a list, or let us work it out from your website.
  2. We match it to every flawOver 400,000 published flaws, checked against your list.
  3. Ranked by real-world riskA 0 to 100 score, led by evidence criminals are using it.
  4. Told as soon as we knowAn alert by email, in the app or by webhook to your own tools.

Free plan, no card needed. Nothing to install.

FAQ

Common questions, answered plainly.

Something else? Talk to the team →

We track 24 published vulnerabilities listed under the name Scalance S615, across 0 versions.

None of Scalance S615's vulnerabilities is on the list of flaws known to be exploited today.

Siemens also lists Scalance S615 under more specific names, such as Scalance S615 Firmware and Scalance S615 Eec Firmware. Flaws listed only under those names are counted on their own pages, not here. Open the release you run to see its own list.

Create a Precursor Intelligence account and track Scalance S615. We match it against every published flaw, give each one a risk score from 0 to 100 and keep watching, so you hear about new ones as soon as we know, by email, in the app or by webhook.